Click to zoom

Please sign in or register to see model options and to add products to your cart.

Product short description:
  • Universal TC type J, K, T, R, S, E, B, N or ±100mV input
  • 4-20mA ouput (sink/source)
  • 12-32 V DC loop/local power

The TT233 model is a space-saving two-wire transmitter that isolates and converts a millivolt or thermocouple sensor input to a proportional 4-20mA control signal. Power is received from the output loop current or a DC supply when using a three-wire connection.

Click here to watch a short AcroMaggie video highlighting the TT230 Series.

 

 

 

 

TT233: Thermocouple / milliVolt Input Two-Wire Transmitter Description

The TT233 model is a space-saving two-wire transmitter that isolates and converts a millivolt or thermocouple sensor input to a proportional 4-20mA control signal. Power is received from the output loop current or a DC supply when using a three-wire connection.

The transmitter performs thermocouple linearization, cold junction compensation, and lead-break detection.

High-voltage isolation separates the input from the output circuit. Isolation protects from surges, reduces noise, and eliminates ground loop errors.

Setup and calibration are fast and easy with a convenient USB connection to your PC and Acromag’s Windows configuration software.

Advanced signal processing capabilities, variable range input, and convenient USB programming make this instrument a very versatile temperature measurement device.

These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions.

Software Options
Windows software allows you to configure transmitters offline, save the file, and download settings into units later, at your convenience.

The Agility™ Config Tool is downloadable (FREE) at the Google Play Store. For Android Devices only.

Learn more about the TT Series of Isolated Transmitters and view all models >

TT233: Thermocouple/mV Input Two-Wire Transmitter Features & Benefits

IMPORTANT: To prevent damage or errors from grounded PCs and surges, Acromag strongly recommends the use of their USB-ISOLATOR when configuring a TT230 Series transmitter.

  • Easy setup and digital calibration via USB with Windows configuration software
  • Easy setup and digital calibration via USB with Windows configuration software
  • Universal thermocouple or millivolt input (TC Type J, K, T, R, S, E, B, N or ±100mV)
  • Space-saving 12.5mm (0.5 inch) unit with pluggable terminals for convenient wiring
  • High accuracy, linearity, stability, and reliability
  • Low temperature drift (<80ppm/°C)
  • User-selectable filtering (none, low, med., high)
  • Supports sink or source output wiring
  • Supports reverse-acting (inverse) output
  • Selectable upscale or downscale operation for sensor errors and lead-break detection
  • 1500V input isolation
  • NAMUR-compliant output loop current
  • Shock (50g) and vibration (5g) resistant
  • Mounts on Type T DIN-rail
  • Wide ambient operation (-40 to 80°C)
  • CE compliant. UL/cUL Class I Div 2, ATEX / IECEx Zone 2 approval

Learn more about the TT Series of Isolated Transmitters and view all models >

Compare Series TT, DT, and SP Single/Dual-Channel Isolated Transmitters and Signal Splitters Guarantee Dependable Value >

How to Minimize Thermocouple to Transmitter Measurement Errors - 8500926 (Log in to view the file)
Preventing Temperature Measurement Error in Thermocouple to Transmitter Connections The nature of thermocouple (TC) circuits is that they’re prone to produce error when mating them to a measurement device; unless you have some insight into how these TCs and their components work. This paper reviews thermocouple behavior and outlines common problems encountered when connecting them...
How to use Thermocouples for Temperature Measurement - 8500911 (Log in to view the file)
Criteria for Temperature Selection of T/C and RTD Sensor Types This is part two of a comprehensive three-part series that provides information for choosing an industrial temperature sensor from Thermocouple (T/C) and Resistance Temperature Detector (RTD) sensor types.   The Basics of Temperature Measurement Using Thermocouples You are probably somewhat familiar with the thermocouple, or...
How to use Thermocouple Transmitters to Monitor Temperatures in Paint Systems - 8400818
This document illustrates using Acromag’s TT330 Series to monitor high temperatures in an automotive paint curing oven and transmit to the existing PLC 4-20mA input card/software setup. Defining the Problem The area around an auto manufacturer’s paint curing ovens is at elevated temperatures affecting the performance of locally installed instrumentation. Placing Signal Conditioners rated for...

Specifications

Manuals

TT233 User Manual (Log in to download the file)

TT230 Series Windows Configuration Software (Log in to download the file)
Agility Config Tool (Tethered) (Log in to download the file)
  • Compare

    TT230-Config/Cal: Calibration Service

    • Factory custom configuration/calibration service.
    • Specify input type, input/output zero and full-scale values, filtering, and sensor fault settings on order.
    Select options
  • Compare

    TTC-SIP: Software

    • Software Interface Package for Acromag DT, ST, TT Series Transmitters and SP, uBSP Series Signal Splitters.
    • Includes configuration sofware CD-ROM (5040-xxx), isolator (USB-ISOLATOR) and two USB cable (4001-112, 4001-113) (Recommend one kit per customer.)
    • Easy setup and digital calibration via USB with Windows configuration software.
    • Download the configuration software only - from the Software Tab
    Select options

Additional information

Weight 8 oz
Dimensions 4.51 × 0.5 × 3.9 in
Part Number

TT233-0600: Transmitter

Configuration

Agility Mobile App, Factory Calibration, USB Configuration, Windows Software Configuration

Product Series

TT230 Series

Power Type

Loop Power

  • Description

    TT233: Thermocouple / milliVolt Input Two-Wire Transmitter Description

    The TT233 model is a space-saving two-wire transmitter that isolates and converts a millivolt or thermocouple sensor input to a proportional 4-20mA control signal. Power is received from the output loop current or a DC supply when using a three-wire connection.

    The transmitter performs thermocouple linearization, cold junction compensation, and lead-break detection.

    High-voltage isolation separates the input from the output circuit. Isolation protects from surges, reduces noise, and eliminates ground loop errors.

    Setup and calibration are fast and easy with a convenient USB connection to your PC and Acromag’s Windows configuration software.

    Advanced signal processing capabilities, variable range input, and convenient USB programming make this instrument a very versatile temperature measurement device.

    These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions.

    Software Options
    Windows software allows you to configure transmitters offline, save the file, and download settings into units later, at your convenience.

    The Agility™ Config Tool is downloadable (FREE) at the Google Play Store. For Android Devices only.

    Learn more about the TT Series of Isolated Transmitters and view all models >

    TT233: Thermocouple/mV Input Two-Wire Transmitter Features & Benefits

    IMPORTANT: To prevent damage or errors from grounded PCs and surges, Acromag strongly recommends the use of their USB-ISOLATOR when configuring a TT230 Series transmitter.

    • Easy setup and digital calibration via USB with Windows configuration software
    • Easy setup and digital calibration via USB with Windows configuration software
    • Universal thermocouple or millivolt input (TC Type J, K, T, R, S, E, B, N or ±100mV)
    • Space-saving 12.5mm (0.5 inch) unit with pluggable terminals for convenient wiring
    • High accuracy, linearity, stability, and reliability
    • Low temperature drift (<80ppm/°C)
    • User-selectable filtering (none, low, med., high)
    • Supports sink or source output wiring
    • Supports reverse-acting (inverse) output
    • Selectable upscale or downscale operation for sensor errors and lead-break detection
    • 1500V input isolation
    • NAMUR-compliant output loop current
    • Shock (50g) and vibration (5g) resistant
    • Mounts on Type T DIN-rail
    • Wide ambient operation (-40 to 80°C)
    • CE compliant. UL/cUL Class I Div 2, ATEX / IECEx Zone 2 approval

    Learn more about the TT Series of Isolated Transmitters and view all models >

    Compare Series TT, DT, and SP Single/Dual-Channel Isolated Transmitters and Signal Splitters Guarantee Dependable Value >

  • Tech Papers

    How to Minimize Thermocouple to Transmitter Measurement Errors - 8500926 (Log in to view the file)
    Preventing Temperature Measurement Error in Thermocouple to Transmitter Connections The nature of thermocouple (TC) circuits is that they’re prone to produce error when mating them to a measurement device; unless you have some insight into how these TCs and their components work. This paper reviews thermocouple behavior and outlines common problems encountered when connecting them...
    How to use Thermocouples for Temperature Measurement - 8500911 (Log in to view the file)
    Criteria for Temperature Selection of T/C and RTD Sensor Types This is part two of a comprehensive three-part series that provides information for choosing an industrial temperature sensor from Thermocouple (T/C) and Resistance Temperature Detector (RTD) sensor types.   The Basics of Temperature Measurement Using Thermocouples You are probably somewhat familiar with the thermocouple, or...
    How to use Thermocouple Transmitters to Monitor Temperatures in Paint Systems - 8400818
    This document illustrates using Acromag’s TT330 Series to monitor high temperatures in an automotive paint curing oven and transmit to the existing PLC 4-20mA input card/software setup. Defining the Problem The area around an auto manufacturer’s paint curing ovens is at elevated temperatures affecting the performance of locally installed instrumentation. Placing Signal Conditioners rated for...
  • Specs & Data Sheets

    Specifications

    Manuals

    TT233 User Manual (Log in to download the file)

  • Software

    TT230 Series Windows Configuration Software (Log in to download the file)
    Agility Config Tool (Tethered) (Log in to download the file)
  • Accessories

    • Compare

      TT230-Config/Cal: Calibration Service

      • Factory custom configuration/calibration service.
      • Specify input type, input/output zero and full-scale values, filtering, and sensor fault settings on order.
      Select options
    • Compare

      TTC-SIP: Software

      • Software Interface Package for Acromag DT, ST, TT Series Transmitters and SP, uBSP Series Signal Splitters.
      • Includes configuration sofware CD-ROM (5040-xxx), isolator (USB-ISOLATOR) and two USB cable (4001-112, 4001-113) (Recommend one kit per customer.)
      • Easy setup and digital calibration via USB with Windows configuration software.
      • Download the configuration software only - from the Software Tab
      Select options
  • Additional information

    Additional information

    Weight 8 oz
    Dimensions 4.51 × 0.5 × 3.9 in
    Part Number

    TT233-0600: Transmitter

    Configuration

    Agility Mobile App, Factory Calibration, USB Configuration, Windows Software Configuration

    Product Series

    TT230 Series

    Power Type

    Loop Power