Click to zoom

Please sign in or register to see model options and to add products to your cart.

Product short description:
  • Dual channels
  • Universal thermocouple, mV input
  • 4-20mA outputs (sink/source)
  • 7-32V DC loop/local

The DT233 model is a dual two-wire transmitter that isolates and converts millivolt or thermocouple sensor inputs to proportional 4-20mA control signals. Power is received from the output loop current.

Click here to watch a short video highlighting the features of the DT233.

 

DT233: Thermocouple / mV Input Two-Wire Dual Transmitter Description

DT230 series signal conditioners provide two independent I/O channels in a single, space-saving unit.

The DT233 model is a dual two-wire transmitter that isolates and converts millivolt or thermocouple sensor inputs to proportional 4-20mA control signals.

Power is received from the output loop current. High-voltage isolation separates all input and output circuits from each other.

Isolation protects from surges, reduces noise, and helps eliminate ground loop errors.

Setup and calibration are fast and easy with a convenient USB connection to your PC and Acromag’s Windows configuration software. The Android app enables setup with mobile devices.

Advanced signal processing capabilities, variable range input/output, and convenient USB programming make this instrument very versatile.

These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions.

Learn more about the DT Series and view all models >

DT233: Thermocouple / mV Input Two-Wire Dual Transmitter Features & Benefits

IMPORTANT: To prevent ground loop error between a grounded PC and a grounded input signal, Acromag strongly recommends use of a USB isolator like Acromag’s USB-Isolator when configuring a DT230 Series transmitter.

  • Operate as a dual transmitter, a single transmitter, or a signal splitter
  • Easy configuration via USB with Windows software or Agility™ app for Android
  • Independently adjustable and scalable input and output ranges
  • Selectable thermocouple/millivolt input types: (TC Type J, K, T, R, S, E, B, N, ±100mV, ±1V)
  • 4-20mA current loop outputs support sinking or sourcing circuit configurations
  • Supports reverse-acting (inverse) output
  • User-configurable output range clamp levels support NAMUR-compliant operation
  • Selectable up/downscale sensor break detection
  • Very low 7V two-wire loop burden
  • High accuracy, linearity, stability, and reliability
  • User-selectable filtering (none, low, med, high)
  • Space-saving 17.5mm (0.7 inch) unit with pluggable terminals for convenient wiring
  • 1500V isolation, 4-way (inputs/outputs)
  • Wide ambient operation (-40 to 80°C)
  • Approvals: CE compliant. UL/cUL Class I Div 2, ATEX/IECEx Zone 2

Learn more about the DT Series and view all models >

Compare Series TT, DT, and SP Single/Dual-Channel Isolated Transmitters and Signal Splitters Guarantee Dependable Value >

How to Minimize Thermocouple to Transmitter Measurement Errors - 8500926 (Log in to view the file)
Preventing Temperature Measurement Error in Thermocouple to Transmitter Connections The nature of thermocouple (TC) circuits is that they’re prone to produce error when mating them to a measurement device; unless you have some insight into how these TCs and their components work. This paper reviews thermocouple behavior and outlines common problems encountered when connecting them...
How to use Thermocouples for Temperature Measurement - 8500911 (Log in to view the file)
Criteria for Temperature Selection of T/C and RTD Sensor Types This is part two of a comprehensive three-part series that provides information for choosing an industrial temperature sensor from Thermocouple (T/C) and Resistance Temperature Detector (RTD) sensor types.   The Basics of Temperature Measurement Using Thermocouples You are probably somewhat familiar with the thermocouple, or...
How to use Thermocouple Transmitters to Monitor Temperatures in Paint Systems - 8400818
This document illustrates using Acromag’s TT330 Series to monitor high temperatures in an automotive paint curing oven and transmit to the existing PLC 4-20mA input card/software setup. Defining the Problem The area around an auto manufacturer’s paint curing ovens is at elevated temperatures affecting the performance of locally installed instrumentation. Placing Signal Conditioners rated for...

Specifications

Manuals

DT233 User Manual (Log in to download the file)

TTC-SIP: Software Interface Package Information Page (Log in to download the file)
DT230 and DT330 Configuration Software (Log in to download the file)
Agility Config Tool (Tethered) (Log in to download the file)
  • Compare

    DT230-Config/Cal: Calibration Service

    • Factory custom configuration/calibration service.
    • Specify input type, input/output zero and full-scale values, filtering, and sensor fault settings on order.
    Select options
  • Compare

    USB Cables

    4001-112: USB cable, 1 meter, with Type A to Type B plugs. 4001-113: USB cable, 1 meter, with Type A to Mini-B plugs. 5028-565: USB-OTG cable, 6 inches
    Select options

Additional information

Weight 8 oz
Dimensions 5 × 5 × 5 in
Part Number

DT233-0600: Dual Transmitter 2-wire TC/mV input

Configuration

Agility Mobile App, Windows Software Configuration

Product Series

DT230 Series

  • Description

    DT233: Thermocouple / mV Input Two-Wire Dual Transmitter Description

    DT230 series signal conditioners provide two independent I/O channels in a single, space-saving unit.

    The DT233 model is a dual two-wire transmitter that isolates and converts millivolt or thermocouple sensor inputs to proportional 4-20mA control signals.

    Power is received from the output loop current. High-voltage isolation separates all input and output circuits from each other.

    Isolation protects from surges, reduces noise, and helps eliminate ground loop errors.

    Setup and calibration are fast and easy with a convenient USB connection to your PC and Acromag’s Windows configuration software. The Android app enables setup with mobile devices.

    Advanced signal processing capabilities, variable range input/output, and convenient USB programming make this instrument very versatile.

    These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions.

    Learn more about the DT Series and view all models >

    DT233: Thermocouple / mV Input Two-Wire Dual Transmitter Features & Benefits

    IMPORTANT: To prevent ground loop error between a grounded PC and a grounded input signal, Acromag strongly recommends use of a USB isolator like Acromag’s USB-Isolator when configuring a DT230 Series transmitter.

    • Operate as a dual transmitter, a single transmitter, or a signal splitter
    • Easy configuration via USB with Windows software or Agility™ app for Android
    • Independently adjustable and scalable input and output ranges
    • Selectable thermocouple/millivolt input types: (TC Type J, K, T, R, S, E, B, N, ±100mV, ±1V)
    • 4-20mA current loop outputs support sinking or sourcing circuit configurations
    • Supports reverse-acting (inverse) output
    • User-configurable output range clamp levels support NAMUR-compliant operation
    • Selectable up/downscale sensor break detection
    • Very low 7V two-wire loop burden
    • High accuracy, linearity, stability, and reliability
    • User-selectable filtering (none, low, med, high)
    • Space-saving 17.5mm (0.7 inch) unit with pluggable terminals for convenient wiring
    • 1500V isolation, 4-way (inputs/outputs)
    • Wide ambient operation (-40 to 80°C)
    • Approvals: CE compliant. UL/cUL Class I Div 2, ATEX/IECEx Zone 2

    Learn more about the DT Series and view all models >

    Compare Series TT, DT, and SP Single/Dual-Channel Isolated Transmitters and Signal Splitters Guarantee Dependable Value >

  • Tech Papers

    How to Minimize Thermocouple to Transmitter Measurement Errors - 8500926 (Log in to view the file)
    Preventing Temperature Measurement Error in Thermocouple to Transmitter Connections The nature of thermocouple (TC) circuits is that they’re prone to produce error when mating them to a measurement device; unless you have some insight into how these TCs and their components work. This paper reviews thermocouple behavior and outlines common problems encountered when connecting them...
    How to use Thermocouples for Temperature Measurement - 8500911 (Log in to view the file)
    Criteria for Temperature Selection of T/C and RTD Sensor Types This is part two of a comprehensive three-part series that provides information for choosing an industrial temperature sensor from Thermocouple (T/C) and Resistance Temperature Detector (RTD) sensor types.   The Basics of Temperature Measurement Using Thermocouples You are probably somewhat familiar with the thermocouple, or...
    How to use Thermocouple Transmitters to Monitor Temperatures in Paint Systems - 8400818
    This document illustrates using Acromag’s TT330 Series to monitor high temperatures in an automotive paint curing oven and transmit to the existing PLC 4-20mA input card/software setup. Defining the Problem The area around an auto manufacturer’s paint curing ovens is at elevated temperatures affecting the performance of locally installed instrumentation. Placing Signal Conditioners rated for...
  • Specs & Data Sheets

    Specifications

    Manuals

    DT233 User Manual (Log in to download the file)

  • Software

    TTC-SIP: Software Interface Package Information Page (Log in to download the file)
    DT230 and DT330 Configuration Software (Log in to download the file)
    Agility Config Tool (Tethered) (Log in to download the file)
  • Accessories

    • Compare

      DT230-Config/Cal: Calibration Service

      • Factory custom configuration/calibration service.
      • Specify input type, input/output zero and full-scale values, filtering, and sensor fault settings on order.
      Select options
    • Compare

      USB Cables

      4001-112: USB cable, 1 meter, with Type A to Type B plugs. 4001-113: USB cable, 1 meter, with Type A to Mini-B plugs. 5028-565: USB-OTG cable, 6 inches
      Select options
  • Additional information

    Additional information

    Weight 8 oz
    Dimensions 5 × 5 × 5 in
    Part Number

    DT233-0600: Dual Transmitter 2-wire TC/mV input

    Configuration

    Agility Mobile App, Windows Software Configuration

    Product Series

    DT230 Series