Click to zoom

Please sign in or register to see model options and to add products to your cart.

Product short description:
  •  Dual channels
  •  ±20mA, ±500mV inputs
  • 4-20mA outputs (sink/source)
  • 7-32V DC loop power

The DT236 model is a dual two-wire transmitter that isolates and converts DC current or low voltage inputs to proportional 4-20mA control signals. Power is received from the output loop current or a DC supply when using a three-wire connection.

Click here to watch a short video highlighting the features of the DT236.

 

DT236: Current/mV Input Two-Wire Dual Transmitter Description

DT230 series signal conditioners provide two independent I/O channels in a single, space-saving unit.

The DT236 model is a dual two-wire transmitter that isolates and converts DC current or low voltage inputs to proportional 4-20mA control signals.

Power is received from the output loop current or a DC supply when using a three-wire connection.

High-voltage isolation separates all input and output circuits from each other.

Isolation protects from surges, reduces noise, and helps eliminate ground loop errors.

Setup and calibration are fast and easy with a convenient USB connection to your PC and Acromag’s Windows configuration software. The Android app enables setup with mobile devices.

Advanced signal processing capabilities, variable range input/output, and convenient USB programming make this instrument very versatile.

These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions.

Learn more about the DT Series and view all models >

DT236: Current / milliVolt Input Two-Wire Dual Transmitter Features & Benefits

  • Operate as a dual transmitter, a single transmitter, or a signal splitter
  • Easy configuration via USB with Windows software or Agility™ app for Android
  • Independently adjustable and scalable: input and output ranges
  • Selectable current and voltage input ranges: 0/4-20mA, ±1mA, ±20mA, ±0.5V, 0-500mV DC
  • Compatible with Acromag 0-20A AC sensor input
  • 4-20mA current loop outputs support sinking or sourcing circuit configurations
  • User-configurable output range clamp levels support NAMUR-compliant operation
  • Very low 7V two-wire loop burden
  • High accuracy, linearity, stability, and reliability
  • User-selectable filtering (none, low, med, high)
  • Space-saving 17.5mm (0.7 inch) unit with pluggable terminals for convenient wiring
  • 1500V isolation, 4-way (inputs/outputs)
  • Wide ambient operation (-40 to 80°C)
  • Approvals: CE compliant. UL/cUL Class I Div 2, ATEX/IECEx Zone 2

Learn more about the DT Series and view all models >

Compare Series TT, DT, and SP Single/Dual-Channel Isolated Transmitters and Signal Splitters Guarantee Dependable Value >

Why Do I Need Electrical Isolation? - 8500988 (Log in to view the file)
Why do we need signal isolation? Acromag is in the business of signal conditioning. We manufacture circuits that amplify, isolate, filter, and convert one signal form to another. Most of these circuits also provide electrical isolation. However, added isolation has a cost. Thus, sometimes customers either question their need for isolation or fail to recognize...
Why You Need USB Isolation for Industrial I/O - 8500-901 (Log in to view the file)
USB Isolation and Industrial I/O Isolation is achieved by removing any direct electrical connection between two devices or portions of a circuit, but having them work as if they were electrically connected. Isolation is generally rated by how high a low current AC voltage can be set before there is arcing across the isolation barrier....
How to Wire a 2 or 4-Wire Current Input Module - 8401048
Application Note: Current Input Wiring: 2-Wire & 4-Wire TT236 / SP236 / DT236 2/3-Wire Transmitters & Splitters TT336 / SP336 / DT336 4-Wire Transmitters & Splitters Featured Products: DT236: Current / milliVolt Input Two-Wire Dual Transmitter DT336: Current / Voltage Input Four-Wire Dual Transmitter SP236: Two-Wire Current / milliVolt Input Signal Splitter SP336: Four-Wire Current...

Specs & Catalogs

Manuals

DT236 User Manual (Log in to download the file)

DT230 and DT330 Configuration Software (Log in to download the file)
Agility Config Tool (Tethered) (Log in to download the file)
  • Compare

    5020-350: Toroidal AC Current Sensor

    • AC Current Sensor to precondition an AC current input signal
    • Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
    Select options
  • Compare

    DT230-Config/Cal: Calibration Service

    • Factory custom configuration/calibration service.
    • Specify input type, input/output zero and full-scale values, filtering, and sensor fault settings on order.
    Select options
  • Compare

    USB Cables

    4001-112: USB cable, 1 meter, with Type A to Type B plugs. 4001-113: USB cable, 1 meter, with Type A to Mini-B plugs. 5028-565: USB-OTG cable, 6 inches
    Select options

Additional information

Weight 16 oz
Dimensions 13 × 12 × 3 in
Part Number

DT236-0600: Isolated 4-20mA Loop-Powered Outputs

Configuration

Agility Mobile App, Windows Software Configuration

Product Series

DT230 Series

  • Description

    DT236: Current/mV Input Two-Wire Dual Transmitter Description

    DT230 series signal conditioners provide two independent I/O channels in a single, space-saving unit.

    The DT236 model is a dual two-wire transmitter that isolates and converts DC current or low voltage inputs to proportional 4-20mA control signals.

    Power is received from the output loop current or a DC supply when using a three-wire connection.

    High-voltage isolation separates all input and output circuits from each other.

    Isolation protects from surges, reduces noise, and helps eliminate ground loop errors.

    Setup and calibration are fast and easy with a convenient USB connection to your PC and Acromag’s Windows configuration software. The Android app enables setup with mobile devices.

    Advanced signal processing capabilities, variable range input/output, and convenient USB programming make this instrument very versatile.

    These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions.

    Learn more about the DT Series and view all models >

    DT236: Current / milliVolt Input Two-Wire Dual Transmitter Features & Benefits

    • Operate as a dual transmitter, a single transmitter, or a signal splitter
    • Easy configuration via USB with Windows software or Agility™ app for Android
    • Independently adjustable and scalable: input and output ranges
    • Selectable current and voltage input ranges: 0/4-20mA, ±1mA, ±20mA, ±0.5V, 0-500mV DC
    • Compatible with Acromag 0-20A AC sensor input
    • 4-20mA current loop outputs support sinking or sourcing circuit configurations
    • User-configurable output range clamp levels support NAMUR-compliant operation
    • Very low 7V two-wire loop burden
    • High accuracy, linearity, stability, and reliability
    • User-selectable filtering (none, low, med, high)
    • Space-saving 17.5mm (0.7 inch) unit with pluggable terminals for convenient wiring
    • 1500V isolation, 4-way (inputs/outputs)
    • Wide ambient operation (-40 to 80°C)
    • Approvals: CE compliant. UL/cUL Class I Div 2, ATEX/IECEx Zone 2

    Learn more about the DT Series and view all models >

    Compare Series TT, DT, and SP Single/Dual-Channel Isolated Transmitters and Signal Splitters Guarantee Dependable Value >

  • Tech Papers

    Why Do I Need Electrical Isolation? - 8500988 (Log in to view the file)
    Why do we need signal isolation? Acromag is in the business of signal conditioning. We manufacture circuits that amplify, isolate, filter, and convert one signal form to another. Most of these circuits also provide electrical isolation. However, added isolation has a cost. Thus, sometimes customers either question their need for isolation or fail to recognize...
    Why You Need USB Isolation for Industrial I/O - 8500-901 (Log in to view the file)
    USB Isolation and Industrial I/O Isolation is achieved by removing any direct electrical connection between two devices or portions of a circuit, but having them work as if they were electrically connected. Isolation is generally rated by how high a low current AC voltage can be set before there is arcing across the isolation barrier....
    How to Wire a 2 or 4-Wire Current Input Module - 8401048
    Application Note: Current Input Wiring: 2-Wire & 4-Wire TT236 / SP236 / DT236 2/3-Wire Transmitters & Splitters TT336 / SP336 / DT336 4-Wire Transmitters & Splitters Featured Products: DT236: Current / milliVolt Input Two-Wire Dual Transmitter DT336: Current / Voltage Input Four-Wire Dual Transmitter SP236: Two-Wire Current / milliVolt Input Signal Splitter SP336: Four-Wire Current...
  • Specs & Data Sheets

    Specs & Catalogs

    Manuals

    DT236 User Manual (Log in to download the file)

  • Software

    DT230 and DT330 Configuration Software (Log in to download the file)
    Agility Config Tool (Tethered) (Log in to download the file)
  • Accessories

    • Compare

      5020-350: Toroidal AC Current Sensor

      • AC Current Sensor to precondition an AC current input signal
      • Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
      Select options
    • Compare

      DT230-Config/Cal: Calibration Service

      • Factory custom configuration/calibration service.
      • Specify input type, input/output zero and full-scale values, filtering, and sensor fault settings on order.
      Select options
    • Compare

      USB Cables

      4001-112: USB cable, 1 meter, with Type A to Type B plugs. 4001-113: USB cable, 1 meter, with Type A to Mini-B plugs. 5028-565: USB-OTG cable, 6 inches
      Select options
  • Additional information

    Additional information

    Weight 16 oz
    Dimensions 13 × 12 × 3 in
    Part Number

    DT236-0600: Isolated 4-20mA Loop-Powered Outputs

    Configuration

    Agility Mobile App, Windows Software Configuration

    Product Series

    DT230 Series