654T: Dual DC Voltage Input, Loop-powered Transmitter
Please sign in or register to see model options and to add products to your cart.
Product short description:
- 2 channels, ±625mV, 0-10V DC (selectable ranges) input
- 4 to 20mA DC output
- 12-50V DC power from output loop
- Dual-channel transmitter with push-button calibration
These units accept DC voltage input signals, provide isolation, and output proportional DC current signals.
654T: Dual DC Voltage Input, Loop-powered Transmitter Description
These units accept DC voltage input signals, provide isolation, and output proportional DC current signals.
With two independent I/O channels in a slim package, the 654T is ideal for panel shops and end-users who require a high-density signal conditioner that can cover a broad range of measurement applications.
Configuration is fast and easy. First, you select the input range for each channel with simple DIP switches. Then, you set your zero/full-scale output values using the non-interactive increase/decrease toggle switches on the front panel to modify the output signal until the desired output value is read on your voltmeter.
The switches make it easy to calibrate a normal proportional) or reverse-acting (inverse) response in seconds. After setting the desired calibration, you can engage the safety lockout feature on the DIP switch to prevent accidental changes and
unauthorized tampering.
The 654T provides two independent high-voltage input isolation circuits. Loss of power or a failure on one channel has no effect on the other. The second channel can be used as a built-in spare for reduced downtime should the first channel fail. The spare channel becomes operational by simply moving the wired terminal block over to the vacant channel.
Input Ranges
Bipolar: ±78mV to ±625mV (selectable ranges).
Unipolar: 0–1.25 to 0–10V DC (selectable ranges).
Output Range
4 to 20mA DC.
Power Requirement
12 to 50V DC (loop-powered).
Two-wire transmitter.
Approvals
UL, cUL listed
Class I; Division 2; Groups A, B, C, D.
Learn more about the 600T Series and see all models >
654T: Dual DC Voltage Input, Loop-powered Transmitter Features & Benefits
- DIP switch-configuration simplifies installation without analog pots, jumpers, or software
- Isolation eliminates ground loops, reduces noise, and blocks transient signals
- One-step calibration with increase/decrease toggle switches simplifies field adjustments for faster and easier maintenance
- Automatic self-calibration compensates for temperature effects and component aging to deliver maintenance-free operation
- Configuration lockout safety feature helps prevent tampering and accidental calibration changes
- Reverse-acting output capability enables inverse proportional control signals
- Dual channel model saves space and reduces equipment costs
- High-resolution 16-bit sigma-delta A/D converters deliver superior accuracy for more reliable measurements
- Built-in transient voltage suppressors protect circuitry from electrical interference
- Operating temperature range: -25 to 75°C (-13 to 167°C)
-
PS5R: Slim Line Power Supplies
- 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
- Universal Input (85-264V AC / 100-370V DC)
- Lightweight and compact size
Additional information
Weight | 8 oz |
---|---|
Dimensions | 1.1 × 5 × 4.5 in |
Part Number | 654T-0600: Transmitter, 654T-0600-C: Transmitter with factory calibration. Specify ranges at checkout |
Product Series | 600 Series |
-
Description
654T: Dual DC Voltage Input, Loop-powered Transmitter Description
These units accept DC voltage input signals, provide isolation, and output proportional DC current signals.
With two independent I/O channels in a slim package, the 654T is ideal for panel shops and end-users who require a high-density signal conditioner that can cover a broad range of measurement applications.
Configuration is fast and easy. First, you select the input range for each channel with simple DIP switches. Then, you set your zero/full-scale output values using the non-interactive increase/decrease toggle switches on the front panel to modify the output signal until the desired output value is read on your voltmeter.
The switches make it easy to calibrate a normal proportional) or reverse-acting (inverse) response in seconds. After setting the desired calibration, you can engage the safety lockout feature on the DIP switch to prevent accidental changes and
unauthorized tampering.The 654T provides two independent high-voltage input isolation circuits. Loss of power or a failure on one channel has no effect on the other. The second channel can be used as a built-in spare for reduced downtime should the first channel fail. The spare channel becomes operational by simply moving the wired terminal block over to the vacant channel.
Input Ranges
Bipolar: ±78mV to ±625mV (selectable ranges).
Unipolar: 0–1.25 to 0–10V DC (selectable ranges).Output Range
4 to 20mA DC.
Power Requirement
12 to 50V DC (loop-powered).
Two-wire transmitter.Approvals
UL, cUL listed
Class I; Division 2; Groups A, B, C, D.Learn more about the 600T Series and see all models >
654T: Dual DC Voltage Input, Loop-powered Transmitter Features & Benefits
- DIP switch-configuration simplifies installation without analog pots, jumpers, or software
- Isolation eliminates ground loops, reduces noise, and blocks transient signals
- One-step calibration with increase/decrease toggle switches simplifies field adjustments for faster and easier maintenance
- Automatic self-calibration compensates for temperature effects and component aging to deliver maintenance-free operation
- Configuration lockout safety feature helps prevent tampering and accidental calibration changes
- Reverse-acting output capability enables inverse proportional control signals
- Dual channel model saves space and reduces equipment costs
- High-resolution 16-bit sigma-delta A/D converters deliver superior accuracy for more reliable measurements
- Built-in transient voltage suppressors protect circuitry from electrical interference
- Operating temperature range: -25 to 75°C (-13 to 167°C)
-
Specs & Data Sheets
-
Accessories
-
PS5R: Slim Line Power Supplies
- 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
- Universal Input (85-264V AC / 100-370V DC)
- Lightweight and compact size
-
-
Additional information
Additional information
Weight 8 oz Dimensions 1.1 × 5 × 4.5 in Part Number 654T-0600: Transmitter, 654T-0600-C: Transmitter with factory calibration. Specify ranges at checkout
Product Series 600 Series
Please login to submit this form.