Click to zoom

Please sign in or register to see model options and to add products to your cart.

Product short description:
  • ±100V DC, 0 to 100mA DC, 0 to 20A AC (with optional sensor) input
  • 0 to 20mA, 0 to 10V DC output
  • 10-36V DC power
  • Universal DC I/O transmitters with auto-configuration and self-ranging capabilities

These units receive DC current or voltage input signals, provide isolation, and output proportional DC current or voltage signals. With support for universal DC I/O ranges, 610T series transmitters provide a solution for a wide variety of isolation and signal conversion tasks.

611T, 612T: Single or Dual Channel, DC Voltage/Current Input, DC-Powered Transmitters Description

These units receive DC current or voltage input signals, provide isolation, and output proportional DC current or voltage signals. With support for universal DC I/O ranges, 610T series transmitters provide a solution for a wide variety of isolation and signal conversion tasks.

The single-channel 611T and dual-channel 612T are ideal for panel shops and end-users who require a high-density signal conditioner that can accommodate a broad range of instrumentation applications.

Installation is fast and simple with Acromag’s built-in auto-configuration feature. Using your standard calibrator, the 610T’s internal microcontroller automatically senses the input source type (voltage or current) and selects the optimum performance range for your zero and full-scale input values.

To adjust your output values, simply push the up or down buttons on the front panel until you read the desired output signal on your meter.

Both models provide high-voltage isolation between the input, output and power (3-way). On dual channel units, each channel operates independently, with inputs isolated from each other, to prevent interaction between channels.

For easy troubleshooting, each channel has diagnostic LEDs to identify input over/under range conditions. An additional status LED indicates the unit is operating properly or that the front panel push button lockout feature has been invoked.

Input Ranges
Universal input with automatic configuration
±100mA (self-ranging)
±100V DC (self-ranging)
0 to 20 amps AC (with optional sensor)

Output Ranges
Universal output (user-configured ranges)
0 to 20mA (full range capability),
0 to 10V DC (full range capability)

Power Requirement: 10 to 36V DC.

Approvals: CE marked. UL, cUL listed.

Learn more about the 600T Series and view all models >

611T, 612T: Single or Dual Channel, DC Voltage/Current Input, DC-Powered Transmitters Features & Benefits

  • Universal DC input and output ranges offer flexibility to fit many applications
  • Auto-configuration and self-ranging technologies speed installation without pots, switches, jumpers, or software
  • Optical isolation eliminates ground loops, reduces noise, and blocks transient signals
  • Push-button calibration simplifies field adjustments for faster and easier maintenance
  • Configuration lockout safety feature prevents tampering and accidental changes
  • Reverse-acting output capability enables inverse proportional control signals
  • Each input channel can drive two outputs (a voltage and a current output signal)
  • Dual channel model saves space and reduces equipment costs
  • High-resolution sigma-delta A/D converters deliver superior accuracy for reliable measurements.
  • Operating temperature range: -25 to 70°C (-13 to 158°F)

Learn more about the 600T Series and view all models >

Why Do I Need Electrical Isolation? - 8500988 (Log in to view the file)
Why do we need signal isolation? Acromag is in the business of signal conditioning. We manufacture circuits that amplify, isolate, filter, and convert one signal form to another. Most of these circuits also provide electrical isolation. However, added isolation has a cost. Thus, sometimes customers either question their need for isolation or fail to recognize...
How to Use a Toroidal AC Current Sensor - 8401044
Using Acromag’s Toroidal AC Current Sensor Model 5020-350 Transmitters with DC current input can be used in conjunction with an external toroidal AC current sensor in order to precondition an AC current input signal. This sensor is a highly accurate toroidal instrument transformer; which converts an AC current signal to a safe, low-level, DC milliampere...

Manuals

611T, 612T User Manual (Log in to download the file)

  • Compare

    5020-350: Toroidal AC Current Sensor

    • AC Current Sensor to precondition an AC current input signal
    • Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
    Select options
  • Compare

    PS5R: Slim Line Power Supplies

    • 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
    • Universal Input (85-264V AC / 100-370V DC)
    • Lightweight and compact size
     
    Select options

Additional information

Weight 16 oz
Dimensions 1.1 × 5 × 4.5 in
Part Number

611T-0500: single I/O channel, 611T-0500-C: single I/O channel with factory calibration, 612T-0500: dual I/O channels, 612T-0500-C: dual I/O channels with factory calibration

Product Series

600 Series

Power Type

DC Power

Configuration

Push Button

  • Description

    611T, 612T: Single or Dual Channel, DC Voltage/Current Input, DC-Powered Transmitters Description

    These units receive DC current or voltage input signals, provide isolation, and output proportional DC current or voltage signals. With support for universal DC I/O ranges, 610T series transmitters provide a solution for a wide variety of isolation and signal conversion tasks.

    The single-channel 611T and dual-channel 612T are ideal for panel shops and end-users who require a high-density signal conditioner that can accommodate a broad range of instrumentation applications.

    Installation is fast and simple with Acromag’s built-in auto-configuration feature. Using your standard calibrator, the 610T’s internal microcontroller automatically senses the input source type (voltage or current) and selects the optimum performance range for your zero and full-scale input values.

    To adjust your output values, simply push the up or down buttons on the front panel until you read the desired output signal on your meter.

    Both models provide high-voltage isolation between the input, output and power (3-way). On dual channel units, each channel operates independently, with inputs isolated from each other, to prevent interaction between channels.

    For easy troubleshooting, each channel has diagnostic LEDs to identify input over/under range conditions. An additional status LED indicates the unit is operating properly or that the front panel push button lockout feature has been invoked.

    Input Ranges
    Universal input with automatic configuration
    ±100mA (self-ranging)
    ±100V DC (self-ranging)
    0 to 20 amps AC (with optional sensor)

    Output Ranges
    Universal output (user-configured ranges)
    0 to 20mA (full range capability),
    0 to 10V DC (full range capability)

    Power Requirement: 10 to 36V DC.

    Approvals: CE marked. UL, cUL listed.

    Learn more about the 600T Series and view all models >

    611T, 612T: Single or Dual Channel, DC Voltage/Current Input, DC-Powered Transmitters Features & Benefits

    • Universal DC input and output ranges offer flexibility to fit many applications
    • Auto-configuration and self-ranging technologies speed installation without pots, switches, jumpers, or software
    • Optical isolation eliminates ground loops, reduces noise, and blocks transient signals
    • Push-button calibration simplifies field adjustments for faster and easier maintenance
    • Configuration lockout safety feature prevents tampering and accidental changes
    • Reverse-acting output capability enables inverse proportional control signals
    • Each input channel can drive two outputs (a voltage and a current output signal)
    • Dual channel model saves space and reduces equipment costs
    • High-resolution sigma-delta A/D converters deliver superior accuracy for reliable measurements.
    • Operating temperature range: -25 to 70°C (-13 to 158°F)

    Learn more about the 600T Series and view all models >

  • Tech Papers

    Why Do I Need Electrical Isolation? - 8500988 (Log in to view the file)
    Why do we need signal isolation? Acromag is in the business of signal conditioning. We manufacture circuits that amplify, isolate, filter, and convert one signal form to another. Most of these circuits also provide electrical isolation. However, added isolation has a cost. Thus, sometimes customers either question their need for isolation or fail to recognize...
    How to Use a Toroidal AC Current Sensor - 8401044
    Using Acromag’s Toroidal AC Current Sensor Model 5020-350 Transmitters with DC current input can be used in conjunction with an external toroidal AC current sensor in order to precondition an AC current input signal. This sensor is a highly accurate toroidal instrument transformer; which converts an AC current signal to a safe, low-level, DC milliampere...
  • Specs & Data Sheets

    Manuals

    611T, 612T User Manual (Log in to download the file)

  • Accessories

    • Compare

      5020-350: Toroidal AC Current Sensor

      • AC Current Sensor to precondition an AC current input signal
      • Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
      Select options
    • Compare

      PS5R: Slim Line Power Supplies

      • 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
      • Universal Input (85-264V AC / 100-370V DC)
      • Lightweight and compact size
       
      Select options
  • Additional information

    Additional information

    Weight 16 oz
    Dimensions 1.1 × 5 × 4.5 in
    Part Number

    611T-0500: single I/O channel, 611T-0500-C: single I/O channel with factory calibration, 612T-0500: dual I/O channels, 612T-0500-C: dual I/O channels with factory calibration

    Product Series

    600 Series

    Power Type

    DC Power

    Configuration

    Push Button