Click to zoom

Please sign in or register to see model options and to add products to your cart.

Product short description:
  • Dual channels
  • ±15V, ±150V inputs
  • 0-20mA, ±10V outputs
  • 6-32V DC local/bus power

The DT338 model is a four-wire dual transmitter that isolates and converts high-level DC voltage inputs to proportional control signals. Each channel supports DC current or voltage output.

Click here to watch a short video highlighting the features of the DT338.

DT338: High DC Voltage Input Four-Wire Dual Transmitter Description

DT330 series signal conditioners provide two independent I/O channels in a single, space-saving unit. The DT338 model is a four-wire dual transmitter that isolates and converts high-level DC voltage inputs to proportional control signals.

Each channel supports DC current or voltage output.

An optional DIN rail bus can deliver primary or redundant power to multiple units.

High-voltage isolation separates inputs, outputs, and power from each other. Isolation protects from surges, reduces noise, and eliminates ground loop errors.

Setup and calibration are fast and easy with a convenient USB connection to your PC and Acromag’s Windows configuration software. The Android app enables setup with mobile devices.

Advanced signal processing capabilities, variable range input/output, and convenient USB programming make this instrument very versatile.

These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions.

IMPORTANT: To prevent damage or errors from grounded PCs and surges, Acromag strongly recommends use of a USB isolator like Acromag’s USB-Isolator when configuring a DT330 Series transmitter.

Learn more about the DT Series and view all models >

DT338: High DC Voltage Input Four-Wire Dual Transmitter Features & Benefits

  • Operate as a dual transmitter, a single transmitter, or a signal splitter
  • Easy configuration via USB with Windows software or Agility™ app for Android
  • Independently adjustable and scalable input and output ranges
  • Selectable high voltage input ranges: ±15V, ±75V, ±150V, 0-15V, 0-75V, 0-150V DC
  • Selectable current and voltage output ranges: 0-20mA, 4-20mA, ±5V, ±10V, 0-5V, 0-10V DC
  • Supports reverse-acting (inverse) output
  • High accuracy, linearity, stability, and reliability
  • User-selectable filtering (none, low, med., high)
  • Bus power, local power, or both (redundancy)
  • Space-saving 17.5mm (0.7 inch) unit with pluggable terminals for convenient wiring
  • 1500V input isolation, 5-way, (power/input/output)
  • Wide ambient operation (-40 to 70°C)
  • Approvals: CE compliant. UL/cUL Class I Div 2, ATEX/IECEx Zone 2

Compare Series TT, DT, and SP Single/Dual-Channel Isolated Transmitters and Signal Splitters Guarantee Dependable Value >

Specs & Catalogs

Manuals

DT338 User Manual (Log in to download the file)

TTC-SIP: Software Interface Package Information Page (Log in to download the file)
DT230 and DT330 Configuration Software (Log in to download the file)
Agility Config Tool (Tethered) (Log in to download the file)
  • Compare

    DT330-Config/Cal: Calibration Service

    • Factory custom configuration/calibration service.
    • Specify input type, input/output zero and full-scale values, filtering, and sensor fault settings on order.
    Select options
  • Compare

    TTBus-Kit: DIN Rail Bus Power Connector

    • One kit supports multiple TT330 series transmitters.
    • For multiple DT330/351 or SP330 transmitters, one TTBUS-KIT is required for each transmitter to be DC Power wired via the bus rail power connections.
       
    Select options
  • Compare

    TTC-SIP: Software

    • Software Interface Package for Acromag DT, ST, TT Series Transmitters and SP, uBSP Series Signal Splitters.
    • Includes configuration sofware CD-ROM (5040-xxx), isolator (USB-ISOLATOR) and two USB cable (4001-112, 4001-113) (Recommend one kit per customer.)
    • Easy setup and digital calibration via USB with Windows configuration software.
    • Download the configuration software only - from the Software Tab
    Select options
  • Compare

    USB Cables

    4001-112: USB cable, 1 meter, with Type A to Type B plugs. 4001-113: USB cable, 1 meter, with Type A to Mini-B plugs. 5028-565: USB-OTG cable, 6 inches
    Select options

Additional information

Weight 16 oz
Dimensions 13 × 12 × 3 in
Part Number

DT338-0700: isolated current or voltage outputs

Configuration

Agility Mobile App, Factory Calibration, Windows Software Configuration

Product Series

DT330 Series

  • Description

    DT338: High DC Voltage Input Four-Wire Dual Transmitter Description

    DT330 series signal conditioners provide two independent I/O channels in a single, space-saving unit. The DT338 model is a four-wire dual transmitter that isolates and converts high-level DC voltage inputs to proportional control signals.

    Each channel supports DC current or voltage output.

    An optional DIN rail bus can deliver primary or redundant power to multiple units.

    High-voltage isolation separates inputs, outputs, and power from each other. Isolation protects from surges, reduces noise, and eliminates ground loop errors.

    Setup and calibration are fast and easy with a convenient USB connection to your PC and Acromag’s Windows configuration software. The Android app enables setup with mobile devices.

    Advanced signal processing capabilities, variable range input/output, and convenient USB programming make this instrument very versatile.

    These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions.

    IMPORTANT: To prevent damage or errors from grounded PCs and surges, Acromag strongly recommends use of a USB isolator like Acromag’s USB-Isolator when configuring a DT330 Series transmitter.

    Learn more about the DT Series and view all models >

    DT338: High DC Voltage Input Four-Wire Dual Transmitter Features & Benefits

    • Operate as a dual transmitter, a single transmitter, or a signal splitter
    • Easy configuration via USB with Windows software or Agility™ app for Android
    • Independently adjustable and scalable input and output ranges
    • Selectable high voltage input ranges: ±15V, ±75V, ±150V, 0-15V, 0-75V, 0-150V DC
    • Selectable current and voltage output ranges: 0-20mA, 4-20mA, ±5V, ±10V, 0-5V, 0-10V DC
    • Supports reverse-acting (inverse) output
    • High accuracy, linearity, stability, and reliability
    • User-selectable filtering (none, low, med., high)
    • Bus power, local power, or both (redundancy)
    • Space-saving 17.5mm (0.7 inch) unit with pluggable terminals for convenient wiring
    • 1500V input isolation, 5-way, (power/input/output)
    • Wide ambient operation (-40 to 70°C)
    • Approvals: CE compliant. UL/cUL Class I Div 2, ATEX/IECEx Zone 2

    Compare Series TT, DT, and SP Single/Dual-Channel Isolated Transmitters and Signal Splitters Guarantee Dependable Value >

  • Specs & Data Sheets

    Specs & Catalogs

    Manuals

    DT338 User Manual (Log in to download the file)

  • Software

    TTC-SIP: Software Interface Package Information Page (Log in to download the file)
    DT230 and DT330 Configuration Software (Log in to download the file)
    Agility Config Tool (Tethered) (Log in to download the file)
  • Accessories

    • Compare

      DT330-Config/Cal: Calibration Service

      • Factory custom configuration/calibration service.
      • Specify input type, input/output zero and full-scale values, filtering, and sensor fault settings on order.
      Select options
    • Compare

      TTBus-Kit: DIN Rail Bus Power Connector

      • One kit supports multiple TT330 series transmitters.
      • For multiple DT330/351 or SP330 transmitters, one TTBUS-KIT is required for each transmitter to be DC Power wired via the bus rail power connections.
         
      Select options
    • Compare

      TTC-SIP: Software

      • Software Interface Package for Acromag DT, ST, TT Series Transmitters and SP, uBSP Series Signal Splitters.
      • Includes configuration sofware CD-ROM (5040-xxx), isolator (USB-ISOLATOR) and two USB cable (4001-112, 4001-113) (Recommend one kit per customer.)
      • Easy setup and digital calibration via USB with Windows configuration software.
      • Download the configuration software only - from the Software Tab
      Select options
    • Compare

      USB Cables

      4001-112: USB cable, 1 meter, with Type A to Type B plugs. 4001-113: USB cable, 1 meter, with Type A to Mini-B plugs. 5028-565: USB-OTG cable, 6 inches
      Select options
  • Additional information

    Additional information

    Weight 16 oz
    Dimensions 13 × 12 × 3 in
    Part Number

    DT338-0700: isolated current or voltage outputs

    Configuration

    Agility Mobile App, Factory Calibration, Windows Software Configuration

    Product Series

    DT330 Series