DT336: Current / milliVolt Input Four-Wire Dual Transmitter
Please sign in or register to see model options and to add products to your cart.
Product short description:
- Dual channels
- ±20mA, ±500mV inputs
- 0-20mA, ±10V outputs
- 6-32V DC local/bus power
The DT336 model is a four-wire dual transmitter that isolates and converts DC current or low voltage inputs to proportional control signals. Each channel supports DC current or voltage output.
Click here to watch a short video highlighting the features of the DT336.
DT336: Current / milliVolt Input Four-Wire Dual Transmitter Description
DT330 series signal conditioners provide two independent I/O channels in a single, space-saving unit.
The DT336 model is a four-wire dual transmitter that isolates and converts DC current or low voltage inputs to proportional control signals.
Each channel supports DC current or voltage output. An optional DIN rail bus can deliver primary or redundant power to multiple units.
High-voltage isolation separates inputs, outputs, and power from each other. Isolation protects from surges, reduces noise, and eliminates ground loop errors.
Setup and calibration are fast and easy with a convenient USB connection to your PC and Acromag’s Windows configuration software. The Android app enables setup with mobile devices.
Advanced signal processing capabilities, variable range input/output, and convenient USB programming make this instrument very versatile.
These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions.
Learn more about the DT Series and view all models >
DT336: Current / milliVolt Input Four-Wire Dual Transmitter Performance Specifications
IMPORTANT: To prevent damage or errors from grounded PCs and surges, Acromag strongly recommends use of a USB isolator like Acromag’s USB-Isolator when configuring a DT330 Series transmitter.
- Operate as a dual transmitter, a single transmitter, or a signal splitter
- Easy configuration via USB with Windows software or Agilityâ„¢ app for Android
- Independently adjustable and scalable input and output ranges
- Selectable current and voltage input ranges: 0/4-20mA, ±1mA, ±20mA, ±0.5V, 0-500mV DC
- Compatible with 0-20A AC sensor input
- Selectable current and voltage output ranges: 0-20mA, 4-20mA, ±5V, ±10V, 0-5V, 0-10V DC
- Supports reverse-acting (inverse) output
- High accuracy, linearity, stability, and reliability
- User-selectable filtering (none, low, med., high)
- Space-saving 17.5mm (0.7 inch) unit with pluggable terminals for convenient wiring
- Bus power, local power, or both (redundancy)
- 1500V input isolation, 5-way, (power/input/output)
- Wide ambient operation (-40 to 70°C)
- Approvals: CE compliant. UL/cUL Class I Div 2, ATEX/IECEx Zone 2
Learn more about the DT Series and view all models >
Compare Series TT, DT, and SP Single/Dual-Channel Isolated Transmitters and Signal Splitters Guarantee Dependable Value >
Specs & Catalogs
Manuals
DT336 User Manual (Log in to download the file)
-
5020-350: Toroidal AC Current Sensor
- AC Current Sensor to precondition an AC current input signal
- Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
-
DT330-Config/Cal: Calibration Service
- Factory custom configuration/calibration service.
- Specify input type, input/output zero and full-scale values, filtering, and sensor fault settings on order.
-
TTBus-Kit: DIN Rail Bus Power Connector
- One kit supports multiple TT330 series transmitters.
- For multiple DT330/351 or SP330 transmitters, one TTBUS-KIT is required for each transmitter to be DC Power wired via the bus rail power connections.
-
TTC-SIP: Software
- Software Interface Package for Acromag DT, ST, TT Series Transmitters and SP, uBSP Series Signal Splitters.
- Includes configuration sofware CD-ROM (5040-xxx), isolator (USB-ISOLATOR) and two USB cable (4001-112, 4001-113) (Recommend one kit per customer.)
- Easy setup and digital calibration via USB with Windows configuration software.
- Download the configuration software only - from the Software Tab
-
USB Cables
4001-112: USB cable, 1 meter, with Type A to Type B plugs. 4001-113: USB cable, 1 meter, with Type A to Mini-B plugs. 5028-565: USB-OTG cable, 6 inches
Additional information
Weight | 16 oz |
---|---|
Dimensions | 13 × 12 × 3 in |
Part Number | DT336-0700: current/millivolt inputs, isolated current or voltage outputs |
Configuration | Agility Mobile App, Factory Calibration, Windows Software Configuration |
Product Series | DT330 Series |
Power Type | DC Power |
-
Description
DT336: Current / milliVolt Input Four-Wire Dual Transmitter Description
DT330 series signal conditioners provide two independent I/O channels in a single, space-saving unit.
The DT336 model is a four-wire dual transmitter that isolates and converts DC current or low voltage inputs to proportional control signals.
Each channel supports DC current or voltage output. An optional DIN rail bus can deliver primary or redundant power to multiple units.
High-voltage isolation separates inputs, outputs, and power from each other. Isolation protects from surges, reduces noise, and eliminates ground loop errors.
Setup and calibration are fast and easy with a convenient USB connection to your PC and Acromag’s Windows configuration software. The Android app enables setup with mobile devices.
Advanced signal processing capabilities, variable range input/output, and convenient USB programming make this instrument very versatile.
These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions.
Learn more about the DT Series and view all models >
DT336: Current / milliVolt Input Four-Wire Dual Transmitter Performance Specifications
IMPORTANT: To prevent damage or errors from grounded PCs and surges, Acromag strongly recommends use of a USB isolator like Acromag’s USB-Isolator when configuring a DT330 Series transmitter.
- Operate as a dual transmitter, a single transmitter, or a signal splitter
- Easy configuration via USB with Windows software or Agilityâ„¢ app for Android
- Independently adjustable and scalable input and output ranges
- Selectable current and voltage input ranges: 0/4-20mA, ±1mA, ±20mA, ±0.5V, 0-500mV DC
- Compatible with 0-20A AC sensor input
- Selectable current and voltage output ranges: 0-20mA, 4-20mA, ±5V, ±10V, 0-5V, 0-10V DC
- Supports reverse-acting (inverse) output
- High accuracy, linearity, stability, and reliability
- User-selectable filtering (none, low, med., high)
- Space-saving 17.5mm (0.7 inch) unit with pluggable terminals for convenient wiring
- Bus power, local power, or both (redundancy)
- 1500V input isolation, 5-way, (power/input/output)
- Wide ambient operation (-40 to 70°C)
- Approvals: CE compliant. UL/cUL Class I Div 2, ATEX/IECEx Zone 2
Learn more about the DT Series and view all models >
Compare Series TT, DT, and SP Single/Dual-Channel Isolated Transmitters and Signal Splitters Guarantee Dependable Value >
-
Tech Papers
How to Wire a 2 or 4-Wire Current Input Module - 8401048Application Note: Current Input Wiring: 2-Wire & 4-Wire TT236 / SP236 / DT236 2/3-Wire Transmitters & Splitters TT336 / SP336 / DT336 4-Wire Transmitters & Splitters Featured Products: DT236: Current / milliVolt Input Two-Wire Dual Transmitter DT336: Current / Voltage Input Four-Wire Dual Transmitter SP236: Two-Wire Current / milliVolt Input Signal Splitter SP336: Four-Wire Current... -
Specs & Data Sheets
Specs & Catalogs
Manuals
DT336 User Manual (Log in to download the file)
-
Software
-
Accessories
-
5020-350: Toroidal AC Current Sensor
- AC Current Sensor to precondition an AC current input signal
- Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
-
DT330-Config/Cal: Calibration Service
- Factory custom configuration/calibration service.
- Specify input type, input/output zero and full-scale values, filtering, and sensor fault settings on order.
-
TTBus-Kit: DIN Rail Bus Power Connector
- One kit supports multiple TT330 series transmitters.
- For multiple DT330/351 or SP330 transmitters, one TTBUS-KIT is required for each transmitter to be DC Power wired via the bus rail power connections.
-
TTC-SIP: Software
- Software Interface Package for Acromag DT, ST, TT Series Transmitters and SP, uBSP Series Signal Splitters.
- Includes configuration sofware CD-ROM (5040-xxx), isolator (USB-ISOLATOR) and two USB cable (4001-112, 4001-113) (Recommend one kit per customer.)
- Easy setup and digital calibration via USB with Windows configuration software.
- Download the configuration software only - from the Software Tab
-
USB Cables
4001-112: USB cable, 1 meter, with Type A to Type B plugs. 4001-113: USB cable, 1 meter, with Type A to Mini-B plugs. 5028-565: USB-OTG cable, 6 inches
-
-
Additional information
Additional information
Weight 16 oz Dimensions 13 × 12 × 3 in Part Number DT336-0700: current/millivolt inputs, isolated current or voltage outputs
Configuration Agility Mobile App, Factory Calibration, Windows Software Configuration
Product Series DT330 Series
Power Type DC Power