Product short description:
  • Dual channels
  •  0-10V, ±10V inputs
  • 4-20mA outputs (sink/source)
  • 7-32V DC loop power

DT230 series signal conditioners provide two independent I/O channels in a single, space-saving unit. The DT237 model is a two-wire dual transmitter that isolates and converts high-level DC voltage inputs to a proportional 4-20mA control signal. Power is received from the output loop current or a DC supply when using a three-wire connection.

Click here to watch a short video highlighting the features of the DT237.

DT237: Medium DC Voltage Input Two-Wire Dual Transmitter Description

DT230 series signal conditioners provide two independent I/O channels in a single, space-saving unit.

The DT237 model is a two-wire dual transmitter that isolates and converts high-level DC voltage inputs to a proportional 4-20mA control signal.

Power is received from the output loop current or a DC supply when using a three-wire connection.

High-voltage isolation separates all input and output circuits from each other. Isolation protects from surges, reduces noise, and eliminates ground loop errors.

Setup and calibration are fast and easy with a convenient USB connection to your PC and Acromag’s Windows configuration software. The Android app enables setup with mobile devices.

Advanced signal processing capabilities, variable range input/output, and convenient USB programming make this instrument very versatile.

These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions.

Learn more about the DT Series and view all models >

DT237: Medium DC Voltage Input Two-Wire Dual Transmitter Features & Benefits

IMPORTANT: To prevent ground loop error between a grounded PC and a grounded input signal, Acromag strongly recommends use of a USB isolator like Acromag’s USB-Isolator when configuring a DT230 Series transmitter.

  • Operate as a dual transmitter, a single transmitter, or a signal splitter
  • Easy configuration via USB with Windows software or Agility™ app for Android
  • Independently adjustable and scalable input and output ranges
  • Selectable voltage input ranges: ±1V, ±5V, ±10V, 0-1V, 0-5V, 0-10V DC
  • 4-20mA current loop outputs support sinking or sourcing circuit configurations
  • Supports reverse-acting (inverse) output
  • User-configurable output range clamp levels support NAMUR-compliant operation
  • Very low 7V two-wire loop burden
  • High accuracy, linearity, stability, and reliability
  • User-selectable filtering (none, low, med, high)
  • Space-saving 17.5mm (0.7 inch) unit with pluggable terminals for convenient wiring
  • 1500V isolation, 4-way (inputs/outputs)
  • Wide ambient operation (-40 to 80°C)
  • Approvals: CE compliant. UL/cUL Class I Div 2, ATEX/IECEx Zone 2

Learn more about the DT Series and view all models >

Compare Series TT, DT, and SP Single/Dual-Channel Isolated Transmitters and Signal Splitters Guarantee Dependable Value >

Specs & Catalogs

Manuals

DT237 User Manual (Log in to download the file)

TTC-SIP: Software Interface Package Information Page (Log in to download the file)
DT230 and DT330 Configuration Software (Log in to download the file)
Agility Config Tool (Tethered) (Log in to download the file)
  • Compare

    DT330-Config/Cal: Calibration Service

    • Factory custom configuration/calibration service.
    • Specify input type, input/output zero and full-scale values, filtering, and sensor fault settings on order.
    Select options
  • Compare

    USB Cables

    4001-112: USB cable, 1 meter, with Type A to Type B plugs. 4001-113: USB cable, 1 meter, with Type A to Mini-B plugs. 5028-565: USB-OTG cable, 6 inches
    Select options

Additional information

Weight 16 oz
Dimensions 13 × 12 × 3 in
Part Number

DT237-0600: Isolated 4-20mA Loop-Powered Outputs

Configuration

Agility Mobile App, Windows Software Configuration

Product Series

DT230 Series

  • Description

    DT237: Medium DC Voltage Input Two-Wire Dual Transmitter Description

    DT230 series signal conditioners provide two independent I/O channels in a single, space-saving unit.

    The DT237 model is a two-wire dual transmitter that isolates and converts high-level DC voltage inputs to a proportional 4-20mA control signal.

    Power is received from the output loop current or a DC supply when using a three-wire connection.

    High-voltage isolation separates all input and output circuits from each other. Isolation protects from surges, reduces noise, and eliminates ground loop errors.

    Setup and calibration are fast and easy with a convenient USB connection to your PC and Acromag’s Windows configuration software. The Android app enables setup with mobile devices.

    Advanced signal processing capabilities, variable range input/output, and convenient USB programming make this instrument very versatile.

    These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions.

    Learn more about the DT Series and view all models >

    DT237: Medium DC Voltage Input Two-Wire Dual Transmitter Features & Benefits

    IMPORTANT: To prevent ground loop error between a grounded PC and a grounded input signal, Acromag strongly recommends use of a USB isolator like Acromag’s USB-Isolator when configuring a DT230 Series transmitter.

    • Operate as a dual transmitter, a single transmitter, or a signal splitter
    • Easy configuration via USB with Windows software or Agility™ app for Android
    • Independently adjustable and scalable input and output ranges
    • Selectable voltage input ranges: ±1V, ±5V, ±10V, 0-1V, 0-5V, 0-10V DC
    • 4-20mA current loop outputs support sinking or sourcing circuit configurations
    • Supports reverse-acting (inverse) output
    • User-configurable output range clamp levels support NAMUR-compliant operation
    • Very low 7V two-wire loop burden
    • High accuracy, linearity, stability, and reliability
    • User-selectable filtering (none, low, med, high)
    • Space-saving 17.5mm (0.7 inch) unit with pluggable terminals for convenient wiring
    • 1500V isolation, 4-way (inputs/outputs)
    • Wide ambient operation (-40 to 80°C)
    • Approvals: CE compliant. UL/cUL Class I Div 2, ATEX/IECEx Zone 2

    Learn more about the DT Series and view all models >

    Compare Series TT, DT, and SP Single/Dual-Channel Isolated Transmitters and Signal Splitters Guarantee Dependable Value >

  • Specs & Data Sheets

    Specs & Catalogs

    Manuals

    DT237 User Manual (Log in to download the file)

  • Software

    TTC-SIP: Software Interface Package Information Page (Log in to download the file)
    DT230 and DT330 Configuration Software (Log in to download the file)
    Agility Config Tool (Tethered) (Log in to download the file)
  • Accessories

    • Compare

      DT330-Config/Cal: Calibration Service

      • Factory custom configuration/calibration service.
      • Specify input type, input/output zero and full-scale values, filtering, and sensor fault settings on order.
      Select options
    • Compare

      USB Cables

      4001-112: USB cable, 1 meter, with Type A to Type B plugs. 4001-113: USB cable, 1 meter, with Type A to Mini-B plugs. 5028-565: USB-OTG cable, 6 inches
      Select options
  • Additional information

    Additional information

    Weight 16 oz
    Dimensions 13 × 12 × 3 in
    Part Number

    DT237-0600: Isolated 4-20mA Loop-Powered Outputs

    Configuration

    Agility Mobile App, Windows Software Configuration

    Product Series

    DT230 Series