Product short description:
  • 4 input channels
  • 0 to 20mA DC (0 to 20A AC with AC sensor) or ±10V DC input range
  • 4 alarm channels, open drain MOSFETS (1A DC loads, 0 to 35V DC)
  • 10 to 36V DC, 24V AC power
  • Modbus RTU high-speed RS-485

This signal conditioner is a four-channel analog input module with four discrete outputs. It provides isolation between input, output, power, and network circuits.

913MB, 914MB: DC Current/Voltage Modbus-RTU Input Module with Limit Alarms Description

This signal conditioner is a four-channel analog input module with four discrete outputs. It provides isolation between input, output, power, and network circuits.

Network communication adheres to the industry-standard RS-485 Modbus RTU protocol. AC and DC power sources are supported with non-polarized, diode-coupled terminals.

The inputs accommodate wide DC voltage or current ranges. Flexible discrete outputs operate as alarms or on/off controllers. As limit alarms, each discrete output can be configured with high and/or low set-points exclusively tied to an analog input channel.

Alarm trips function without host communication enabling low-cost stand-alone alarms, as well as local backup for the primary control system. Otherwise, on/off control is based on commands issued by the host system.

Combining flexible transmitter functions, mixed signal I/O, alarm support, and a network interface in a single package, makes this instrument extremely powerful. Multi-channel design adds cost-efficiency and allows high-density mounting.

Plus, safe, rugged construction makes these modules reliable for use in both control room and distributed field I/O applications. Custom module configurations are also possible (consult factory for details).

Learn about the 900MB Series and view all models >

913MB, 914MB: DC Current/Voltage Modbus-RTU Input Module with Limit Alarms Features & Benefits

  • Standard Modbus RTU protocol with high-speed RS-485 communication (up to 115K bps)
  • 16-bit sigma-delta A/D yields 0.1% of range resolution and accuracy
  • Four inputs in a single inch-wide module reduces system costs and saves panel space
  • Four discrete outputs enable local limit alarms or host-controlled on/off switching
  • Heavy-duty 1A solid-state relays provide dependable on/off control of industrial devices
  • Self-calibration lowers maintenance costs by reducing periodic manual calibration checks
  • Watchdog timers provide a configurable fail-safe output state for use when host I/O communication is lost
  • Four-way isolation eliminates potential ground loops between power, input, output, and network circuitry
  • Self-diagnostics monitor micro-controller activity to detect operational failures (lock-up) and execute a reset to restore communication
  • Operating temperature: -25°C to 70°C (-13°F to 158°F).

Learn about the 900MB Series and view all models >

  • 4 input channels
  • 0 to 20mA DC (0 to 20A AC with AC sensor) or ±10V DC input range
  • 4 alarm channels, open drain MOSFETS (1A DC loads, 0 to 35V DC)
  • 10 to 36V DC, 24V AC power
  • Modbus RTU high-speed RS-485
This signal conditioner is a four-channel analog input module with four discrete outputs. It provides isolation between input, output, power, and network circuits.
What is EtherNet/IP? White Paper - 8500747 (Log in to view the file)
Introduction to EtherNet/IP What is EtherNet/IP (Ethernet Industrial Protocol)? EtherNet/IP is traditional Ethernet combined with an industrial application layer protocol targeted to industrial automation. This application layer protocol is the Control and Information Protocol (CIPâ„¢). In this whitepaper, you will review the basic aspects of EtherNet/IP and learn how the open-source protocol can benefit your...
What is Modbus/RS485? An Introduction - 8500648 (Log in to view the file)
Modbus/RS485 Network an Introduction White Paper This white paper describes the operation of Modbus as it relates to Acromag Series 900MB I/O modules.   Learn more: What is Ethernet/IP?
How to Configure Kepware KEPServerEX 5.0 for Communications with Modbus I/O Modules - 8500880
Configuring Kepware KEPServerEX 5.0 for Communications with Acromag BusWorks Modbus I/O Modules Introduction This document provides example steps for configuring the Kepware KEPServerEX OPC Server for communications with Acromag Busworks Modbus RTU and Modbus TCP/IP Distributed I/O Modules. Once the server is configured, data may be read from or written to the I/O module using...
How to Configure LabVIEW to Communicate with Modbus I/O Modules Via an OPC Server - 8500881
Configuring LabVIEW 2009 to Communicate with Acromag BusWorks and EtherStax Modbus I/O Modules via an OPC Server Introduction National Instruments™ LabVIEW can be used to monitor and control Acromag BusWorks ® and EtherStax ® Modbus I/O modules via an OPC server. A separate application note, Configuring Kepware KEPServerEX® 5.0 for communications with Acromag BusWorks and EtherStax...

Manuals

913MB, 914MB User Manual (Log in to download the file)

How to Use SIIG USB-to-Serial Cable With Windows Tech Note (Log in to download the file)

IntelliPack & Series 900MB Configuration Software Windows 7 or 8 User Manual (Log in to download the file)

IntelliPack & Series 900 Configuration Software: Windows 10 User Manual (Log in to download the file)

900C-SIP: Modbus RTU Configuration Software Information Page (Log in to download the file)
  • Compare

    5020-350: Toroidal AC Current Sensor

    • AC Current Sensor to precondition an AC current input signal
    • Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
    Select options
  • Compare

    5034-202: RS-485 to 3-wire Cable Converter and Cable

    RS-485 to 3-wire cable converter and cable, DB-9M to 3 x 12AWG RS-485 cable, 8 ft.
    Select options
  • Compare

    5034-214: RS232 to RS485 Serial Port Converter

    Non-isolated RS232-to-RS485 serial port converter, RS232 port-powered, DB-9F to DB-9F.
    Select options
  • Compare

    900C-SIP: Configuration Software Interface Package

    • Configuration Software
    • USB-to-RS232 Adapter
    • RS232-to-RS485 Adapter
    • Interface Cable
     
    Select options

Additional information

Weight 16 oz
Dimensions 13 × 12 × 3 in
Part Number

913MB-0900: 4 current input channels, 914MB-0900: 4 voltage input channels

Configuration

Windows Software Configuration

Communication

Modbus-RTU, RS422/485

Product Series

BusWorks 900MB

  • Description

    913MB, 914MB: DC Current/Voltage Modbus-RTU Input Module with Limit Alarms Description

    This signal conditioner is a four-channel analog input module with four discrete outputs. It provides isolation between input, output, power, and network circuits.

    Network communication adheres to the industry-standard RS-485 Modbus RTU protocol. AC and DC power sources are supported with non-polarized, diode-coupled terminals.

    The inputs accommodate wide DC voltage or current ranges. Flexible discrete outputs operate as alarms or on/off controllers. As limit alarms, each discrete output can be configured with high and/or low set-points exclusively tied to an analog input channel.

    Alarm trips function without host communication enabling low-cost stand-alone alarms, as well as local backup for the primary control system. Otherwise, on/off control is based on commands issued by the host system.

    Combining flexible transmitter functions, mixed signal I/O, alarm support, and a network interface in a single package, makes this instrument extremely powerful. Multi-channel design adds cost-efficiency and allows high-density mounting.

    Plus, safe, rugged construction makes these modules reliable for use in both control room and distributed field I/O applications. Custom module configurations are also possible (consult factory for details).

    Learn about the 900MB Series and view all models >

    913MB, 914MB: DC Current/Voltage Modbus-RTU Input Module with Limit Alarms Features & Benefits

    • Standard Modbus RTU protocol with high-speed RS-485 communication (up to 115K bps)
    • 16-bit sigma-delta A/D yields 0.1% of range resolution and accuracy
    • Four inputs in a single inch-wide module reduces system costs and saves panel space
    • Four discrete outputs enable local limit alarms or host-controlled on/off switching
    • Heavy-duty 1A solid-state relays provide dependable on/off control of industrial devices
    • Self-calibration lowers maintenance costs by reducing periodic manual calibration checks
    • Watchdog timers provide a configurable fail-safe output state for use when host I/O communication is lost
    • Four-way isolation eliminates potential ground loops between power, input, output, and network circuitry
    • Self-diagnostics monitor micro-controller activity to detect operational failures (lock-up) and execute a reset to restore communication
    • Operating temperature: -25°C to 70°C (-13°F to 158°F).

    Learn about the 900MB Series and view all models >

  • Tech Papers

    • 4 input channels
    • 0 to 20mA DC (0 to 20A AC with AC sensor) or ±10V DC input range
    • 4 alarm channels, open drain MOSFETS (1A DC loads, 0 to 35V DC)
    • 10 to 36V DC, 24V AC power
    • Modbus RTU high-speed RS-485
    This signal conditioner is a four-channel analog input module with four discrete outputs. It provides isolation between input, output, power, and network circuits.
    What is EtherNet/IP? White Paper - 8500747 (Log in to view the file)
    Introduction to EtherNet/IP What is EtherNet/IP (Ethernet Industrial Protocol)? EtherNet/IP is traditional Ethernet combined with an industrial application layer protocol targeted to industrial automation. This application layer protocol is the Control and Information Protocol (CIPâ„¢). In this whitepaper, you will review the basic aspects of EtherNet/IP and learn how the open-source protocol can benefit your...
    What is Modbus/RS485? An Introduction - 8500648 (Log in to view the file)
    Modbus/RS485 Network an Introduction White Paper This white paper describes the operation of Modbus as it relates to Acromag Series 900MB I/O modules.   Learn more: What is Ethernet/IP?
    How to Configure Kepware KEPServerEX 5.0 for Communications with Modbus I/O Modules - 8500880
    Configuring Kepware KEPServerEX 5.0 for Communications with Acromag BusWorks Modbus I/O Modules Introduction This document provides example steps for configuring the Kepware KEPServerEX OPC Server for communications with Acromag Busworks Modbus RTU and Modbus TCP/IP Distributed I/O Modules. Once the server is configured, data may be read from or written to the I/O module using...
    How to Configure LabVIEW to Communicate with Modbus I/O Modules Via an OPC Server - 8500881
    Configuring LabVIEW 2009 to Communicate with Acromag BusWorks and EtherStax Modbus I/O Modules via an OPC Server Introduction National Instruments™ LabVIEW can be used to monitor and control Acromag BusWorks ® and EtherStax ® Modbus I/O modules via an OPC server. A separate application note, Configuring Kepware KEPServerEX® 5.0 for communications with Acromag BusWorks and EtherStax...
  • Specs & Data Sheets

    Manuals

    913MB, 914MB User Manual (Log in to download the file)

    How to Use SIIG USB-to-Serial Cable With Windows Tech Note (Log in to download the file)

    IntelliPack & Series 900MB Configuration Software Windows 7 or 8 User Manual (Log in to download the file)

    IntelliPack & Series 900 Configuration Software: Windows 10 User Manual (Log in to download the file)

  • Software

    900C-SIP: Modbus RTU Configuration Software Information Page (Log in to download the file)
  • Accessories

    • Compare

      5020-350: Toroidal AC Current Sensor

      • AC Current Sensor to precondition an AC current input signal
      • Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
      Select options
    • Compare

      5034-202: RS-485 to 3-wire Cable Converter and Cable

      RS-485 to 3-wire cable converter and cable, DB-9M to 3 x 12AWG RS-485 cable, 8 ft.
      Select options
    • Compare

      5034-214: RS232 to RS485 Serial Port Converter

      Non-isolated RS232-to-RS485 serial port converter, RS232 port-powered, DB-9F to DB-9F.
      Select options
    • Compare

      900C-SIP: Configuration Software Interface Package

      • Configuration Software
      • USB-to-RS232 Adapter
      • RS232-to-RS485 Adapter
      • Interface Cable
       
      Select options
  • Additional information

    Additional information

    Weight 16 oz
    Dimensions 13 × 12 × 3 in
    Part Number

    913MB-0900: 4 current input channels, 914MB-0900: 4 voltage input channels

    Configuration

    Windows Software Configuration

    Communication

    Modbus-RTU, RS422/485

    Product Series

    BusWorks 900MB