Click to zoom

Please sign in or register to see model options and to add products to your cart.

Product short description:
  • 4 Analog DC Current Outputs
  • 4 Discrete Voltage I/O Channels
  • 12 to 32V DC Power (2.8W)
  • Modbus TCP/IP, Ethernet/IP, Profinet
  • i2o® peer-to-peer available for Modbus TCP/IP only

The XT1530 interfaces analog output and discrete I/O signals between measurement and control devices over Ethernet. Discrete I/O are individually configurable for input or high-side switched output operation.

XT1530: Analog Output & Digital I/O Ethernet Modules Description

The XT1530 interfaces analog output and discrete I/O signals between measurement and control devices over Ethernet.

Discrete I/O are individually configurable for input or high-side switched output operation.

Rugged construction, high density design, and easy USB-to-PC/Windows setup combine for a very effective I/O solution.

These units are ideal for remote monitoring, distributed control, or SCADA applications.

Analog Output Ranges: 0-20mA DC, 4-20mA DC.

Discrete Input/Output Ranges
Input: 0-32V DC, TTL thresholds.
Output: 0-32V DC, open-source, up to 250mA.

Ethernet Communication
Modbus TCP/IP, i2o® peer-to-peer available for Modbus TCP/IP only. Ethernet/IP, Profinet, 10/100Base-T(X), PriorityChannel™ device determinism.

Power Requirement: 12 to 32V DC (2.8W).

Learn more about the Ethernet XT Series and view all models >

XT1530: Analog Output & Digital I/O Ethernet Modules Performance Specifications

IMPORTANT: To prevent damage or errors from grounded PCs and surges, Acromag strongly recommends use of the USB-ISOLATOR when configuring an XT1000 I/O module.

USB Interface

USB Connector

Type: USB Mini-B type socket, 5-pin.
Data Rate: 12Mbps. USB v1.1 and 2.0 compatible.

Cable Length: 5.0 meters maximum.

USB Transient Protection: Transient voltage suppression on power and data lines.

Driver: Not required. Uses Windows (HID) drivers.

Analog Output

Configuration: 4 output channels, each with a 16-bit D/A converter.

Output Type: 0-20mA DC or 4-20mA DC, configurable by channel.

Accuracy: Better than ±0.1% of span.

Output Excitation: Separate inputs for 12V (10-15V) and 24V (20-28V) power sources. Diode-coupled to support redundancy.

Discrete Input

Input Type: 4 active-high, buffered inputs, with a common connection. Inputs are tied in tandem to output drains for optional loopback monitoring of output state.

Input Signal Voltage Range: 0 to 32V DC.

Input Current: 280μA, typical at 32V DC.

Input Signal Threshold: 1.7V DC typical with100mV of hysteresis.

Input Resistance: 10K ohms, typical.

Input Response Time: 10ms, nominal.

Discrete Output

Output Type: 4 open-source, smart, p-channel mosfet switches with a common drain connection. Provides high-side (sourcing) switching between the load and return.

Output Signal Voltage Range: 0 to 32V DC. 6-32V excitation source required.

Output “ON” Resistance: 0.5 ohms typical, 1.0 ohms maximum.

Output “ON” Current Range: 0 to 250mA DC, continuous (up to 1A total for all 4 channels combined).

Output Response Time: 10ms, nominal.

Ethernet Communication

Protocols: Modbus TCP/IP, i2o® peer-to-peer available for Modbus TCP/IP only, Ethernet/IP or Profinet, depending on model number.

Ethernet Communication Controller: Innovasic RapID™ Platform with PriorityChannel™ for determinism at the device regardless of network load.

Modbus TCP/IP (slave): Port 502 reserved. Supports up to 10 sockets.

i2o Peer-to-Peer (master/slave): Can map 4-channel input groups to output groups at two destination IP addresses. Timed or change-of-state updates. Supports GPRS/GSM systems.

Ethernet/IP (adapter): Supports 16 connections. EDS file on website.

Profinet (server): Supports 1 connection. GSDML file on website.

Connectors: Two shielded 8-pin RJ-45 sockets, 10BaseT/100BaseTX.

Wiring: Auto-crossover for MDI or MDI-X.

IP Address: User-configurable. 192.168.1.100 default static IP address.

Data Rate: Auto-negotiated, 10Mbps or 100Mbps.

Compliance: IEEE 802.3, 802.3u, 802.3x

Environmental

Operating Temperature: -40 to 60°C (-40 to 140°F).

Storage Temperature: -40 to 85°C (-40 to 185°F).

Relative Humidity: 5 to 95% non-condensing.

Power Requirement: 12 to 32V DC (110mA maximum @ 24V).

Isolation: I/O channels (as a group), network (each port), and power circuits isolated from each other.
Peak: 1500V AC, ANSI/ISA-82.01-1988.
Continuous: 250V AC, 354V DC.

MTBF: 445,034 hrs. at 25°C; 335,836 hrs. at 40°C

Shock Immunity: 25g, per IEC 60068-2-27

Vibration Immunity: 4g, per IEC 60068-2-64

Approvals: CE compliant. UL/cUL listings. Class I; Division 2; Groups ABCD; Zone 2. ATEX Certified.

Electromagnetic Compatibility (EMC) Compliance
Radiated Emissions: BS EN 61000-6-4, CISPR 16
RFI: BS EN 61000-6-2, IEC 61000-4-3
Conducted RFI: BS EN 61000-6-2, IEC 61000-4-6
ESD: BS EN 61000-6-2, IEC 61000-4-2
EFT: BS EN 61000-6-2, IEC 61000-4-4
Surge Immunity: BS EN 61000-6-2, IEC 61000-4-5

Physical

General: General purpose plastic enclosure for mounting on 35mm “T-type” DIN rail.

Case Material: Self-extinguishing polyamide, UL94 V-0 rated, color light gray. General purpose NEMA Type 1 enclosure.

Circuit Board: Military grade fire-retardant epoxy glass (IPC-4101/98).

I/O Connectors: Removable plug-in type terminal blocks rated for 12A/250V; AWG #26-12, stranded/solid copper wire.

Dimensions:
Width = 22.5mm (0.9 inches).
Length = 114.5mm (4.51 inches).
Depth = 99.0mm (3.90 inches).

Shipping Weight: 0.5 pounds (0.22 Kg) packed.

Learn more about the Ethernet XT Series and view all models >

  • i2o® peer-to-peer available for Modbus TCP/IP only
  • i2o® peer-to-peer updates based on change-of-state and/or timed updates
  • Multi-function, multi-channel stand alone module is very economical
  • Built-in 10K ohm pull-down resistors for 2/3-wire sensors (contacts, proximity, TTL)
  • Configurable normal/reverse input logic
  • Outputs include built-in read-back capability
  • Easy setup with Windows software via USB
  • Continuously changing “heart-beat” register validates module operation
  • High-Density 22.5mm wide package with pluggable, front-facing terminals
  • Dual Ethernet 10/100 ports (auto-negotiation) reduce switch port requirements
  • 1500V AC isolation (between I/O, power, and network ports) and surge/transient protection
  • Supports bussed/rail and redundant power
  • -40°C to 70°C wide temperature operation
  • Withstands 25g shock and 4g vibration
  • CE and UL/cUL Class 1 Div 2 Zone 2 approvals
  • ATEX Certified.
How to Communicate with Acromag Ethernet/IP Modules from CompactLogix Controllers - 8500762
Communicating with Acromag Series 9xxEN-60xx,  XTxxx2-xxx, and NTE2xxx-xxxx Ethernet/IP™ Modules from CompactLogix™ PLC Device This document illustrates a procedure for configuring message commands intended for Acromag Busworks® Series Ethernet/IP modules using Ladder Logic programming software in addition to a CompactLogix Programmable Controller. It is assumed that the user has a working knowledge of; Ladder Logic...
How to Communicate with Modbus/TCP Modules from Ignition Software - 8501121
Setting Up and Communicating with Acromag Series 9xxEN-40xx and XTxxx1-xxx Modbus/TCP Modules and EtherStax™ Modbus/TCP from Ignition Software This document illustrates a procedure for configuring OPC tags intended for Acromag BusWorks® Series Modbus/TCP modules using Windows software from Inductive Automation. It is assumed that the user has a working knowledge of OPC, Modbus TCP, and...
How to Save Money Using i2o Over Cellular Networks - 8400921
Minimizing Costs When Transmitting Data Over Cellular Networks How to Save Money Using i2o Over Cellular Networks: Acromag has a peer-to-peer technology called i2o. It allows two or more modules to talk to each other; without a network master or special software. Additionally, i2o operates over any standard Ethernet media; Cat 5 or 6 copper,...
How to Connect to Acromag Ethernet I/O Devices - 8500815
Getting Connected to Acromag Ethernet I/O Devices These instructions summarize the basic steps you will have to take in order to initially connect an Acromag Ethernet I/O product to your Personal Computer (PC) or laptop. To connect an Ethernet device to your PC, consult with your network administrator. Either temporarily change the TCP/IP configuration of...
How to Communicate with Ethernet XT Profinet from Siemens S7-1200 PLC - 8501007
Communicating with Acromag Model XTxxx3-000 Profinet I/O Modules from a Siemens S7-1200 PLC EthernetXT Profinet and Siemens S7-1200 When setting up a Profinet network, Profinet controllers are programmed with a special Profinet Configuration tool, like the Step7 from Siemens. This document illustrates an example procedure for configuring communications between Acromag BusWorks® Series Profinet modules and...

Manuals

XT1531 User Manual (Log in to download the file)

XT1532 User Manual (Log in to download the file)

XT1533 User Manual (Log in to download the file)

XT-SIP: Software Interface Information Page (Log in to download the file)
Ethernet XT Series Configuration Software (Log in to download the file)
ESW-MBLIB: Ethernet Modbus C Library Software Information Page (Log in to download the file)
AMTx: Modbus TCP/IP Software Information Page (Log in to download the file)
Profinet GSDML Files for XTxxx3-000 Modules (Log in to download the file)
Ethernet IP EDS For XTxxx2-000 Modules (Log in to download the file)
  • Compare

    5035 Series: Ethernet Cables

    • Ethernet straight cable, CAT5
    • Ethernet crossover cable, CAT5E
    • Low EMI Double-Shielded Ethernet Patch Cable
    Select options
  • Compare

    XT-SIP: Software Interface Package

    • Software Interface Package for BusWorks XT Series Ethernet I/O modules.
    • Easy setup and digital calibration via USB with Windows configuration software
    • Download software only from the Software Tab below
    Select options

Additional information

Weight 8 oz
Dimensions 4.5 × 1.5 × 5 in
Product Name

XT1531-000: Modbus TCP/IP and i2o protocol, XT1532-000: Ethernet/IP protocol, XT1533-000: PROFINET protocol

Part Number

XT1531-000: Modbus/TCP and i2o protocol, XT1532-000: Ethernet/IP protocol, XT1533-000: PROFINET protocol

Communication

Ethernet/IP, i2o Peer-to-Peer, Modbus TCP/IP, Profinet

Configuration

USB Configuration, Windows Software Configuration

Product Series

BusWorks XT Series

  • Description

    XT1530: Analog Output & Digital I/O Ethernet Modules Description

    The XT1530 interfaces analog output and discrete I/O signals between measurement and control devices over Ethernet.

    Discrete I/O are individually configurable for input or high-side switched output operation.

    Rugged construction, high density design, and easy USB-to-PC/Windows setup combine for a very effective I/O solution.

    These units are ideal for remote monitoring, distributed control, or SCADA applications.

    Analog Output Ranges: 0-20mA DC, 4-20mA DC.

    Discrete Input/Output Ranges
    Input: 0-32V DC, TTL thresholds.
    Output: 0-32V DC, open-source, up to 250mA.

    Ethernet Communication
    Modbus TCP/IP, i2o® peer-to-peer available for Modbus TCP/IP only. Ethernet/IP, Profinet, 10/100Base-T(X), PriorityChannel™ device determinism.

    Power Requirement: 12 to 32V DC (2.8W).

    Learn more about the Ethernet XT Series and view all models >

    XT1530: Analog Output & Digital I/O Ethernet Modules Performance Specifications

    IMPORTANT: To prevent damage or errors from grounded PCs and surges, Acromag strongly recommends use of the USB-ISOLATOR when configuring an XT1000 I/O module.

    USB Interface

    USB Connector

    Type: USB Mini-B type socket, 5-pin.
    Data Rate: 12Mbps. USB v1.1 and 2.0 compatible.

    Cable Length: 5.0 meters maximum.

    USB Transient Protection: Transient voltage suppression on power and data lines.

    Driver: Not required. Uses Windows (HID) drivers.

    Analog Output

    Configuration: 4 output channels, each with a 16-bit D/A converter.

    Output Type: 0-20mA DC or 4-20mA DC, configurable by channel.

    Accuracy: Better than ±0.1% of span.

    Output Excitation: Separate inputs for 12V (10-15V) and 24V (20-28V) power sources. Diode-coupled to support redundancy.

    Discrete Input

    Input Type: 4 active-high, buffered inputs, with a common connection. Inputs are tied in tandem to output drains for optional loopback monitoring of output state.

    Input Signal Voltage Range: 0 to 32V DC.

    Input Current: 280μA, typical at 32V DC.

    Input Signal Threshold: 1.7V DC typical with100mV of hysteresis.

    Input Resistance: 10K ohms, typical.

    Input Response Time: 10ms, nominal.

    Discrete Output

    Output Type: 4 open-source, smart, p-channel mosfet switches with a common drain connection. Provides high-side (sourcing) switching between the load and return.

    Output Signal Voltage Range: 0 to 32V DC. 6-32V excitation source required.

    Output “ON” Resistance: 0.5 ohms typical, 1.0 ohms maximum.

    Output “ON” Current Range: 0 to 250mA DC, continuous (up to 1A total for all 4 channels combined).

    Output Response Time: 10ms, nominal.

    Ethernet Communication

    Protocols: Modbus TCP/IP, i2o® peer-to-peer available for Modbus TCP/IP only, Ethernet/IP or Profinet, depending on model number.

    Ethernet Communication Controller: Innovasic RapID™ Platform with PriorityChannel™ for determinism at the device regardless of network load.

    Modbus TCP/IP (slave): Port 502 reserved. Supports up to 10 sockets.

    i2o Peer-to-Peer (master/slave): Can map 4-channel input groups to output groups at two destination IP addresses. Timed or change-of-state updates. Supports GPRS/GSM systems.

    Ethernet/IP (adapter): Supports 16 connections. EDS file on website.

    Profinet (server): Supports 1 connection. GSDML file on website.

    Connectors: Two shielded 8-pin RJ-45 sockets, 10BaseT/100BaseTX.

    Wiring: Auto-crossover for MDI or MDI-X.

    IP Address: User-configurable. 192.168.1.100 default static IP address.

    Data Rate: Auto-negotiated, 10Mbps or 100Mbps.

    Compliance: IEEE 802.3, 802.3u, 802.3x

    Environmental

    Operating Temperature: -40 to 60°C (-40 to 140°F).

    Storage Temperature: -40 to 85°C (-40 to 185°F).

    Relative Humidity: 5 to 95% non-condensing.

    Power Requirement: 12 to 32V DC (110mA maximum @ 24V).

    Isolation: I/O channels (as a group), network (each port), and power circuits isolated from each other.
    Peak: 1500V AC, ANSI/ISA-82.01-1988.
    Continuous: 250V AC, 354V DC.

    MTBF: 445,034 hrs. at 25°C; 335,836 hrs. at 40°C

    Shock Immunity: 25g, per IEC 60068-2-27

    Vibration Immunity: 4g, per IEC 60068-2-64

    Approvals: CE compliant. UL/cUL listings. Class I; Division 2; Groups ABCD; Zone 2. ATEX Certified.

    Electromagnetic Compatibility (EMC) Compliance
    Radiated Emissions: BS EN 61000-6-4, CISPR 16
    RFI: BS EN 61000-6-2, IEC 61000-4-3
    Conducted RFI: BS EN 61000-6-2, IEC 61000-4-6
    ESD: BS EN 61000-6-2, IEC 61000-4-2
    EFT: BS EN 61000-6-2, IEC 61000-4-4
    Surge Immunity: BS EN 61000-6-2, IEC 61000-4-5

    Physical

    General: General purpose plastic enclosure for mounting on 35mm “T-type” DIN rail.

    Case Material: Self-extinguishing polyamide, UL94 V-0 rated, color light gray. General purpose NEMA Type 1 enclosure.

    Circuit Board: Military grade fire-retardant epoxy glass (IPC-4101/98).

    I/O Connectors: Removable plug-in type terminal blocks rated for 12A/250V; AWG #26-12, stranded/solid copper wire.

    Dimensions:
    Width = 22.5mm (0.9 inches).
    Length = 114.5mm (4.51 inches).
    Depth = 99.0mm (3.90 inches).

    Shipping Weight: 0.5 pounds (0.22 Kg) packed.

    Learn more about the Ethernet XT Series and view all models >

  • Features & Benefits

    • i2o® peer-to-peer available for Modbus TCP/IP only
    • i2o® peer-to-peer updates based on change-of-state and/or timed updates
    • Multi-function, multi-channel stand alone module is very economical
    • Built-in 10K ohm pull-down resistors for 2/3-wire sensors (contacts, proximity, TTL)
    • Configurable normal/reverse input logic
    • Outputs include built-in read-back capability
    • Easy setup with Windows software via USB
    • Continuously changing “heart-beat” register validates module operation
    • High-Density 22.5mm wide package with pluggable, front-facing terminals
    • Dual Ethernet 10/100 ports (auto-negotiation) reduce switch port requirements
    • 1500V AC isolation (between I/O, power, and network ports) and surge/transient protection
    • Supports bussed/rail and redundant power
    • -40°C to 70°C wide temperature operation
    • Withstands 25g shock and 4g vibration
    • CE and UL/cUL Class 1 Div 2 Zone 2 approvals
    • ATEX Certified.
  • Tech Papers

    How to Communicate with Acromag Ethernet/IP Modules from CompactLogix Controllers - 8500762
    Communicating with Acromag Series 9xxEN-60xx,  XTxxx2-xxx, and NTE2xxx-xxxx Ethernet/IP™ Modules from CompactLogix™ PLC Device This document illustrates a procedure for configuring message commands intended for Acromag Busworks® Series Ethernet/IP modules using Ladder Logic programming software in addition to a CompactLogix Programmable Controller. It is assumed that the user has a working knowledge of; Ladder Logic...
    How to Communicate with Modbus/TCP Modules from Ignition Software - 8501121
    Setting Up and Communicating with Acromag Series 9xxEN-40xx and XTxxx1-xxx Modbus/TCP Modules and EtherStax™ Modbus/TCP from Ignition Software This document illustrates a procedure for configuring OPC tags intended for Acromag BusWorks® Series Modbus/TCP modules using Windows software from Inductive Automation. It is assumed that the user has a working knowledge of OPC, Modbus TCP, and...
    How to Save Money Using i2o Over Cellular Networks - 8400921
    Minimizing Costs When Transmitting Data Over Cellular Networks How to Save Money Using i2o Over Cellular Networks: Acromag has a peer-to-peer technology called i2o. It allows two or more modules to talk to each other; without a network master or special software. Additionally, i2o operates over any standard Ethernet media; Cat 5 or 6 copper,...
    How to Connect to Acromag Ethernet I/O Devices - 8500815
    Getting Connected to Acromag Ethernet I/O Devices These instructions summarize the basic steps you will have to take in order to initially connect an Acromag Ethernet I/O product to your Personal Computer (PC) or laptop. To connect an Ethernet device to your PC, consult with your network administrator. Either temporarily change the TCP/IP configuration of...
    How to Communicate with Ethernet XT Profinet from Siemens S7-1200 PLC - 8501007
    Communicating with Acromag Model XTxxx3-000 Profinet I/O Modules from a Siemens S7-1200 PLC EthernetXT Profinet and Siemens S7-1200 When setting up a Profinet network, Profinet controllers are programmed with a special Profinet Configuration tool, like the Step7 from Siemens. This document illustrates an example procedure for configuring communications between Acromag BusWorks® Series Profinet modules and...
  • Specs & Data Sheets

    Manuals

    XT1531 User Manual (Log in to download the file)

    XT1532 User Manual (Log in to download the file)

    XT1533 User Manual (Log in to download the file)

  • Software

    XT-SIP: Software Interface Information Page (Log in to download the file)
    Ethernet XT Series Configuration Software (Log in to download the file)
    ESW-MBLIB: Ethernet Modbus C Library Software Information Page (Log in to download the file)
    AMTx: Modbus TCP/IP Software Information Page (Log in to download the file)
    Profinet GSDML Files for XTxxx3-000 Modules (Log in to download the file)
    Ethernet IP EDS For XTxxx2-000 Modules (Log in to download the file)
  • Accessories

    • Compare

      5035 Series: Ethernet Cables

      • Ethernet straight cable, CAT5
      • Ethernet crossover cable, CAT5E
      • Low EMI Double-Shielded Ethernet Patch Cable
      Select options
    • Compare

      XT-SIP: Software Interface Package

      • Software Interface Package for BusWorks XT Series Ethernet I/O modules.
      • Easy setup and digital calibration via USB with Windows configuration software
      • Download software only from the Software Tab below
      Select options
  • Additional information

    Additional information

    Weight 8 oz
    Dimensions 4.5 × 1.5 × 5 in
    Product Name

    XT1531-000: Modbus TCP/IP and i2o protocol, XT1532-000: Ethernet/IP protocol, XT1533-000: PROFINET protocol

    Part Number

    XT1531-000: Modbus/TCP and i2o protocol, XT1532-000: Ethernet/IP protocol, XT1533-000: PROFINET protocol

    Communication

    Ethernet/IP, i2o Peer-to-Peer, Modbus TCP/IP, Profinet

    Configuration

    USB Configuration, Windows Software Configuration

    Product Series

    BusWorks XT Series