SP333: Four-Wire Thermocouple / milliVolt Splitter
Please sign in or register to see model options and to add products to your cart.
Product short description:
- Universal thermocouple or ±100mV input
- 0-20mA, ±10V or 0-10V outputs
- 6-32V DC external power
The SP333 is a high-performance signal splitter that converts one millivolt or thermocouple input into two isolated proportional control signals. A variety of current and voltage output ranges are supported.
Click here to watch a short video highlighting the features of the Acromag SP Series.
SP333: Four-Wire Thermocouple / mV Splitter Description
The SP333 is a high-performance signal splitter that converts one millivolt or thermocouple input into two isolated proportional control signals. A variety of current and voltage output ranges are supported.
Power connects on a terminal block, a rail bus, or both for redundancy.
High-voltage isolation separates the input from power and each output circuit. The isolation protects from surges, reduces noise, and eliminates ground loop errors.
Setup is fast and easy with a USB connection to your PC and our Windows software. Acromag’s Agility™ mobile app enables configuration on an Android smart phone or tablet.
Software simplifies I/O range scaling, calibration, and advanced signal processing capabilities.
These rugged instruments withstand harsh industrial environments to operate reliably across a wide temperature range with very low drift. They feature high immunity to RFI, EMI, ESD, and EFT, plus low radiated emissions.
IMPORTANT: To prevent ground loop error between a grounded PC and a grounded input signal, Acromag strongly recommends use of a USB isolator like Acromag’s USB-Isolator when configuring a SP330 Series transmitter.
Learn more about the SP Series and view all models >
SP333: Four-Wire TC/mV Splitter Features & Benefits
- Easy configuration via USB with Windows software or Agility app for Android
- Universal thermocouple or millivolt input (TC Type J, K, T, R, S, E, B, N or ±100mV)
- Input can scale differently for each output
- User-selectable filtering (none, low, med, high)
- Scalable current or voltage output ranges: 0-20mA, 4-20mA, ±5V, ±10V, 0-5V, 0-10V
- Normal or reverse-acting output
- Wide-range DC power input from 6-32V with support for rail power bus and redundancy
- High accuracy, linearity, stability, and reliability
- 1500V isolation
- Space-saving 17.5mm (0.69 inch) design with pluggable terminals for easier wiring
- Shock (25g) and vibration (4g) resistant
- Wide ambient operation (-40 to 75°C)
- CE compliant. UL/cUL Class I Div 2, ATEX / IECEx Zone 2 approvals
Learn more about the SP Series and view all models >
Compare Series TT, DT, and SP Single/Dual-Channel Isolated Transmitters and Signal Splitters Guarantee Dependable Value >
Specifications
Manuals
SP333 User Manual (Log in to download the file)
Brochures
Drawings & Diagrams
-
TTBus-Kit: DIN Rail Bus Power Connector
- One kit supports multiple TT330 series transmitters.
- For multiple DT330/351 or SP330 transmitters, one TTBUS-KIT is required for each transmitter to be DC Power wired via the bus rail power connections.
-
TTC-SIP: Software
- Software Interface Package for Acromag DT, ST, TT Series Transmitters and SP, uBSP Series Signal Splitters.
- Includes configuration sofware CD-ROM (5040-xxx), isolator (USB-ISOLATOR) and two USB cable (4001-112, 4001-113) (Recommend one kit per customer.)
- Easy setup and digital calibration via USB with Windows configuration software.
- Download the configuration software only - from the Software Tab
-
USB Cables
4001-112: USB cable, 1 meter, with Type A to Type B plugs. 4001-113: USB cable, 1 meter, with Type A to Mini-B plugs. 5028-565: USB-OTG cable, 6 inches
Additional information
Weight | 8 oz |
---|---|
Dimensions | 4 × 4.75 × 1 in |
Part Number | SP333-0700: Splitter |
Configuration | Agility Mobile App, USB Configuration, Windows Software Configuration |
Product Series | SP330 Series |
Power Type | External Power |
-
Description
SP333: Four-Wire Thermocouple / mV Splitter Description
The SP333 is a high-performance signal splitter that converts one millivolt or thermocouple input into two isolated proportional control signals. A variety of current and voltage output ranges are supported.
Power connects on a terminal block, a rail bus, or both for redundancy.
High-voltage isolation separates the input from power and each output circuit. The isolation protects from surges, reduces noise, and eliminates ground loop errors.
Setup is fast and easy with a USB connection to your PC and our Windows software. Acromag’s Agility™ mobile app enables configuration on an Android smart phone or tablet.
Software simplifies I/O range scaling, calibration, and advanced signal processing capabilities.
These rugged instruments withstand harsh industrial environments to operate reliably across a wide temperature range with very low drift. They feature high immunity to RFI, EMI, ESD, and EFT, plus low radiated emissions.
IMPORTANT: To prevent ground loop error between a grounded PC and a grounded input signal, Acromag strongly recommends use of a USB isolator like Acromag’s USB-Isolator when configuring a SP330 Series transmitter.
Learn more about the SP Series and view all models >
SP333: Four-Wire TC/mV Splitter Features & Benefits
- Easy configuration via USB with Windows software or Agility app for Android
- Universal thermocouple or millivolt input (TC Type J, K, T, R, S, E, B, N or ±100mV)
- Input can scale differently for each output
- User-selectable filtering (none, low, med, high)
- Scalable current or voltage output ranges: 0-20mA, 4-20mA, ±5V, ±10V, 0-5V, 0-10V
- Normal or reverse-acting output
- Wide-range DC power input from 6-32V with support for rail power bus and redundancy
- High accuracy, linearity, stability, and reliability
- 1500V isolation
- Space-saving 17.5mm (0.69 inch) design with pluggable terminals for easier wiring
- Shock (25g) and vibration (4g) resistant
- Wide ambient operation (-40 to 75°C)
- CE compliant. UL/cUL Class I Div 2, ATEX / IECEx Zone 2 approvals
Learn more about the SP Series and view all models >
Compare Series TT, DT, and SP Single/Dual-Channel Isolated Transmitters and Signal Splitters Guarantee Dependable Value >
-
Tech Papers
What is Circuit Grounding and Why is it Important? - 8500993 (Log in to view the file)Why is Circuit Grounding Important? This whitepaper is Part 1 of a three-part Grounding Electrical Equipment Best Practices series that looks at grounding and its role in protecting personnel, equipment, and ensuring the integrity of electrical signals. In this part, we will review circuit grounding and its importance to you, as well as the US...How Do Ground Fault Circuit Interrupters Work & Protect Us from Shock? - 8500020 (Log in to view the file)How do ground fault circuit interrupters work? This Electrical Ground Rules white paper is Part 2 of a three-part series that takes a look at grounding and its role in protecting personnel and equipment, and ensuring the integrity of electrical signals. In this part, we will examine our use of ground as a means of...How does Ground Work as a Voltage Stabilizer and Transient Limiter? - 8501021 (Log in to view the file)What is the role of ground as a voltage stabilizer and transient limiter? This Electrical Ground Rules whitepaper is Part 3 of a three-part series that takes a look at grounding and its role in protecting personnel and equipment, and ensuring the integrity of electrical signals. Consideration of ground can be very complex and application... -
Specs & Data Sheets
Specifications
Manuals
SP333 User Manual (Log in to download the file)
Brochures
Drawings & Diagrams
-
Software
-
Accessories
-
TTBus-Kit: DIN Rail Bus Power Connector
- One kit supports multiple TT330 series transmitters.
- For multiple DT330/351 or SP330 transmitters, one TTBUS-KIT is required for each transmitter to be DC Power wired via the bus rail power connections.
-
TTC-SIP: Software
- Software Interface Package for Acromag DT, ST, TT Series Transmitters and SP, uBSP Series Signal Splitters.
- Includes configuration sofware CD-ROM (5040-xxx), isolator (USB-ISOLATOR) and two USB cable (4001-112, 4001-113) (Recommend one kit per customer.)
- Easy setup and digital calibration via USB with Windows configuration software.
- Download the configuration software only - from the Software Tab
-
USB Cables
4001-112: USB cable, 1 meter, with Type A to Type B plugs. 4001-113: USB cable, 1 meter, with Type A to Mini-B plugs. 5028-565: USB-OTG cable, 6 inches
-
-
Additional information
Additional information
Weight 8 oz Dimensions 4 × 4.75 × 1 in Part Number SP333-0700: Splitter
Configuration Agility Mobile App, USB Configuration, Windows Software Configuration
Product Series SP330 Series
Power Type External Power
Please login to submit this form.