Product short description:
- Multi-range ±20mA or ±500mV input
- Universal current/voltage output
- 12-32V DC power
DC current and voltage output are both supported on a single model. An optional DIN rail bus can deliver primary or redundant power to multiple units without wiring.
Click here to watch a short video highlighting the TT330 Series.
TT336: Current/mV Input, DC Power Transmitter Description
DC current and voltage output are both supported on a single model. An optional DIN rail bus can deliver primary or redundant power to multiple units without wiring.
High-voltage isolation separates the input from the output circuit. Isolation protects from surges, reduces noise, and eliminates ground loop errors.
Setup and calibration are fast and easy with a convenient USB connection to your PC and Acromag’s Windows configuration software.
Advanced signal processing capabilities, variable range input, and convenient USB programming make this instrument a very versatile temperature measurement device.
These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions.
Learn more about the TT Series and view all models >
TT336: Current / mV Input, DC Power Transmitter Features & Benefits
- Easy setup and digital calibration via USB with Windows configuration software
- Single unit supports unipolar and bipolar input ranges up to ±20mA or ±500mV DC
- Compatible with 0-20A AC sensor input
- Universal output connections support ranges up to ±21mA or ±10.5V DC without rewiring
- Space-saving 17.5mm (0.7 inch) unit with pluggable terminals for convenient wiring
- High accuracy, linearity, stability, and reliability
- User-selectable filtering (low, medium, high)
- Adjustable response time (10ms to 1200ms)
- Supports reverse-acting (inverse) output
- Bus power, local power, or both
- Redundant power ready (rail/local)
- 1500V input isolation, 3-way (power, input, output)
- Shock (50g) and vibration (5g) resistant
- Mounts on Type T DIN-rail
- Wide ambient operation (-40 to 80°C)
- CE compliant. UL/cUL Class I Div 2, ATEX / IECEx Zone 2 approvals
Learn more about the TT Series and view all models >
Compare Series TT, DT, and SP Single/Dual-Channel Isolated Transmitters and Signal Splitters Guarantee Dependable Value >
-
5020-350: Toroidal AC Current Sensor
- AC Current Sensor to precondition an AC current input signal
- Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
-
TT330-Config/Cal: Calibration Service
- Factory custom configuration/calibration service.
- Specify input type, input/output zero and full-scale values, filtering, and sensor fault settings on order.
-
TTBus-Kit: DIN Rail Bus Power Connector
- One kit supports multiple TT330 series transmitters.
- For multiple DT330/351 or SP330 transmitters, one TTBUS-KIT is required for each transmitter to be DC Power wired via the bus rail power connections.
-
TTC-SIP: Software
- Software Interface Package for Acromag DT, ST, TT Series Transmitters and SP, uBSP Series Signal Splitters.
- Includes configuration sofware CD-ROM (5040-xxx), isolator (USB-ISOLATOR) and two USB cable (4001-112, 4001-113) (Recommend one kit per customer.)
- Easy setup and digital calibration via USB with Windows configuration software.
- Download the configuration software only - from the Software Tab
Additional information
Weight | 8 oz |
---|---|
Dimensions | 4.51 × 0.5 × 3.9 in |
Part Number | TT336-0700: Four-wire transmitter |
Configuration | Agility Mobile App, Factory Calibration, USB Configuration, Windows Software Configuration |
Product Series | TT330 Series |
Power Type | DC Power |
-
Description
TT336: Current/mV Input, DC Power Transmitter Description
DC current and voltage output are both supported on a single model. An optional DIN rail bus can deliver primary or redundant power to multiple units without wiring.
High-voltage isolation separates the input from the output circuit. Isolation protects from surges, reduces noise, and eliminates ground loop errors.
Setup and calibration are fast and easy with a convenient USB connection to your PC and Acromag’s Windows configuration software.
Advanced signal processing capabilities, variable range input, and convenient USB programming make this instrument a very versatile temperature measurement device.
These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions.
Learn more about the TT Series and view all models >
TT336: Current / mV Input, DC Power Transmitter Features & Benefits
- Easy setup and digital calibration via USB with Windows configuration software
- Single unit supports unipolar and bipolar input ranges up to ±20mA or ±500mV DC
- Compatible with 0-20A AC sensor input
- Universal output connections support ranges up to ±21mA or ±10.5V DC without rewiring
- Space-saving 17.5mm (0.7 inch) unit with pluggable terminals for convenient wiring
- High accuracy, linearity, stability, and reliability
- User-selectable filtering (low, medium, high)
- Adjustable response time (10ms to 1200ms)
- Supports reverse-acting (inverse) output
- Bus power, local power, or both
- Redundant power ready (rail/local)
- 1500V input isolation, 3-way (power, input, output)
- Shock (50g) and vibration (5g) resistant
- Mounts on Type T DIN-rail
- Wide ambient operation (-40 to 80°C)
- CE compliant. UL/cUL Class I Div 2, ATEX / IECEx Zone 2 approvals
Learn more about the TT Series and view all models >
Compare Series TT, DT, and SP Single/Dual-Channel Isolated Transmitters and Signal Splitters Guarantee Dependable Value >
-
Tech Papers
How to Wire a 2 or 4-Wire Current Input Module - 8401048Application Note: Current Input Wiring: 2-Wire & 4-Wire TT236 / SP236 / DT236 2/3-Wire Transmitters & Splitters TT336 / SP336 / DT336 4-Wire Transmitters & Splitters Featured Products: DT236: Current / milliVolt Input Two-Wire Dual Transmitter DT336: Current / Voltage Input Four-Wire Dual Transmitter SP236: Two-Wire Current / milliVolt Input Signal Splitter SP336: Four-Wire Current...How to Re-transmit and Isolate 4-20mA Signals from Remotely-Mounted 3-Wire Gas Detection Sensors - 8400957Defining the Problem: Signals from 3-wire remote sensors that monitor combustible and toxic gases are typically transmitted directly to the remote gas monitor or controller. However, in some cases, it’s desirable to send the signal to more than one destination. This can either be accomplished by re-transmitting the existing signal to additional locations; or by...How to Select a 4-20mA Isolator - 8400850 (Log in to view the file)Click here to download How to Select a 4-20mA Isolator Introduction Acromag manufactures a variety of isolators to provide a cost effective solution for many applications. The main reasons for using an isolator are to: eliminate bucking power supplies; protect expensive control room equipment from transient spikes; and break ground loops that may exist between...Why Do I Need Electrical Isolation? - 8500988 (Log in to view the file)Why do we need signal isolation? Acromag is in the business of signal conditioning. We manufacture circuits that amplify, isolate, filter, and convert one signal form to another. Most of these circuits also provide electrical isolation. However, added isolation has a cost. Thus, sometimes customers either question their need for isolation or fail to recognize... -
Specs & Data Sheets
-
Software
-
Accessories
-
5020-350: Toroidal AC Current Sensor
- AC Current Sensor to precondition an AC current input signal
- Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
-
TT330-Config/Cal: Calibration Service
- Factory custom configuration/calibration service.
- Specify input type, input/output zero and full-scale values, filtering, and sensor fault settings on order.
-
TTBus-Kit: DIN Rail Bus Power Connector
- One kit supports multiple TT330 series transmitters.
- For multiple DT330/351 or SP330 transmitters, one TTBUS-KIT is required for each transmitter to be DC Power wired via the bus rail power connections.
-
TTC-SIP: Software
- Software Interface Package for Acromag DT, ST, TT Series Transmitters and SP, uBSP Series Signal Splitters.
- Includes configuration sofware CD-ROM (5040-xxx), isolator (USB-ISOLATOR) and two USB cable (4001-112, 4001-113) (Recommend one kit per customer.)
- Easy setup and digital calibration via USB with Windows configuration software.
- Download the configuration software only - from the Software Tab
-
-
Additional information
Additional information
Weight 8 oz Dimensions 4.51 × 0.5 × 3.9 in Part Number TT336-0700: Four-wire transmitter
Configuration Agility Mobile App, Factory Calibration, USB Configuration, Windows Software Configuration
Product Series TT330 Series
Power Type DC Power