Showing 17–32 of 62 results
-
XT1230: 16-Channel Single-Ended Analog Current Input Module
- 0-11mA, 0-20mA, 4-20mA, ±20mA, or 0-20 amps AC Input
- 16 analog single-ended current input channels
- 12 to 32V DC Power (2.8W)
- Modbus TCP/IP, Ethernet/IP, Profinet
- i2o® peer-to-peer available for Modbus TCP/IP only
-
DT238: High DC Voltage Input Two-Wire Dual Transmitter
- Dual inputs
- 0±150V input
- 4-20mA outputs (sink/source)
- 7-32V DC loop/local power
-
TT231: RTD / Resistance Input Two-Wire Transmitter
- 100 ohm Pt RTD or 0-900 ohm input
- 4-20mA output (sink/source)
- 12-32V DC loop/local power
- USB configuration
-
XT1240: 16-Channel Single-ended Analog DC Voltage Input Module
- Input: ±5V, ±10V, 0-5V, 0-10V
- 16 analog single-ended voltage input channels
- 12 to 32V DC Power (2.8W)
- Modbus TCP/IP, Ethernet/IP, Profinet
- i2o® peer-to-peer available for Modbus TCP/IP only
-
XT1120: 16-Channel Discrete Ethernet I/O Modules with Sourcing Outputs
- 16 discrete tandem input/output channels
- Modbus TCP/IP, Ethernet/IP, Profinet, or i20 communication
-
XT1530: Analog Output & Digital I/O Ethernet Modules
- 4 Analog DC Current Outputs
- 4 Discrete Voltage I/O Channels
- 12 to 32V DC Power (2.8W)
- Modbus TCP/IP, Ethernet/IP, Profinet
- i2o® peer-to-peer available for Modbus TCP/IP only
-
XT1540: Analog Output & Digital I/O Ethernet Modules
- 8 Analog DC Voltage Outputs ±10V (calibrated), ±5V (sub-range)
- 4 Discrete Voltage I/O Channels 0-32V DC
- 12 to 32V DC Power (2.8W)
- Modbus TCP/IP, Ethernet/IP, Profinet
- i2o® peer-to-peer available for Modbus TCP/IP only
-
801A Universal TC/RTD/mV Input Intelligent Alarm
- Thermocouple (J, K, T, R, S, E, B, N), RTD (Pt, Ni, Cu), millivolt (±100mV DC), resistance (0 to 500 ohms) input
- Single or dual mechanical relay alarm outputs
- 10-36V DC power
- Software configured
- Multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection)
- On/off controller capability
-
801T: Universal Input Intelligent Temperature Transmitter
- Thermocouple, RTD, milliVolt, and Resistance Input
- 0 to 20mA DC, 0 to 10V DC output
- Limit Alarm
- 10-36V DC power
- Software configured
- Performs linearization, square root extraction, and optional limit alarm functions
-
811A, 812A: Intelligent Alarm; DC Voltage/Current Input
- ±100V or 0 to 22mA DC input ranges or 2 input channels, ±100V or 0 to 22mA DC input ranges (AC current with optional sensor)
- Single or dual mechanical relays
- 10-36V DC power
- Software configured; multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection); on/off controller capability
-
811T: DC Voltage/Current Input Intelligent Transmitter
- ±100V or 0 to 22mA DC input ranges (AC current with optional sensor)
- 0 to 20mA DC, 0 to 10V DC output
- Mechanical relay alarm (25V @ 5A)
- 10-36V DC power
- Software configured, performs linearization, square root extraction, and optional limit alarm functions
-
822A Dual Thermocouple/mV Input Intelligent Alarm
- 2 input channels, thermocouple (types J, K, T, R, S, E, B, N), or millivolt (±100mV DC) input
- Dual mechanical relays output
- 10-36V DC power
- Software configured; multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection); on/off controller capability
-
841T: DC Frequency/Pulse Input Intelligent Transmitter
- 0 to 50KHz, 0 to 65535 pulses input
- 0 to 20mA DC, 0 to 10V DC output
- Mechanical alarm relay (25V @ 5A)
- 10-36V DC power
- Software configured; pulse counter; signal averaging; optional limit alarm functions
-
892M, 894M: DC Voltage/Current Output Math Module
- 2 or 4Â input channels, 0 to 20mA DC, 0 to 10V DC (selectable ranges)
- 0 to 20mA DC, 0 to 10V DC (selectable ranges) output
- 10-36V DC power
- Software configured, computes arithmetic operations, evaluates conditional and Boolean arguments, executes track & hold functions
-
895M, 896M: DC Input, Frequency Output Math Module
- 0 to 20mA DC, 0 to 10V DC (selectable ranges), 896M 2 channels input
- 0 to 10KHz, 0 to 36,000 counts/hr Frequency output, 896M 2 channels
- Solid-state relay (60V DC @ 500mA) control output
- 10-36V DC power
- Software configured, ideal for integrator/totalizer applications, computes arithmetic operations, conditional arguments, track & hold functions
-
901MB, 902MB, 903MB: Multi-Channel Modbus-RTU Discrete I/O Modules
- Active-Low Inputs, Sinking Outputs (Low-Side Switching)
- 12 input and/or 12 output channels
- 0 to 35V DC I/O range
- 10 to 36V DC, 24V AC power
- Modbus-RTU high-speed RS-485