Showing 17–32 of 62 results

  • Compare

    XT1230: 16-Channel Single-Ended Analog Current Input Module

    • 0-11mA, 0-20mA, 4-20mA, ±20mA, or 0-20 amps AC Input
    • 16 analog single-ended current input channels
    • 12 to 32V DC Power (2.8W)
    • Modbus TCP/IP, Ethernet/IP, Profinet
    • i2o® peer-to-peer available for Modbus TCP/IP only
    The XT1230 offers an isolated Ethernet network interface for up to to sixteen single-ended current input channels.
    Select options
  • Compare

    DT238: High DC Voltage Input Two-Wire Dual Transmitter

    • Dual inputs
    • 0±150V input
    • 4-20mA outputs (sink/source)
    • 7-32V DC loop/local power
    The DT238 model is a two-wire dual transmitter that isolates and converts high-level DC voltage inputs to proportional 4-20mA control signals. Power is received from the output loop current or a DC supply when using a three-wire connection. Click here to watch a short video highlighting the features of the DT238.
    Select options
  • Compare

    TT231: RTD / Resistance Input Two-Wire Transmitter

    • 100 ohm Pt RTD or 0-900 ohm input
    • 4-20mA output (sink/source)
    • 12-32V DC loop/local power
    • USB configuration
    The TT231 model is a space-saving two-wire transmitter that converts a 100 ohm Platinum RTD sensor input to a proportional 4-20mA signal. Power is received from the output loop current or a DC supply when using a three-wire connection. Click here to watch a short AcroMaggie video highlighting the TT230 Series.
    Select options
  • Compare

    XT1240: 16-Channel Single-ended Analog DC Voltage Input Module

    • Input: ±5V, ±10V, 0-5V, 0-10V
    • 16 analog single-ended voltage input channels
    • 12 to 32V DC Power (2.8W)
    • Modbus TCP/IP, Ethernet/IP, Profinet
    • i2o® peer-to-peer available for Modbus TCP/IP only
    The XT1240 offers an isolated Ethernet network interface for up to to sixteen single-ended voltage input channels.
    Select options
  • Compare

    XT1120: 16-Channel Discrete Ethernet I/O Modules with Sourcing Outputs

    • 16 discrete tandem input/output channels
    • Modbus TCP/IP, Ethernet/IP, Profinet, or i20 communication
    The XT1120 interfaces discrete I/O signals between measurement and control devices over Ethernet. Channels are individually configurable for input or high-side switched output operation.
    Select options
  • Compare

    XT1530: Analog Output & Digital I/O Ethernet Modules

    • 4 Analog DC Current Outputs
    • 4 Discrete Voltage I/O Channels
    • 12 to 32V DC Power (2.8W)
    • Modbus TCP/IP, Ethernet/IP, Profinet
    • i2o® peer-to-peer available for Modbus TCP/IP only
    The XT1530 interfaces analog output and discrete I/O signals between measurement and control devices over Ethernet. Discrete I/O are individually configurable for input or high-side switched output operation.
    Select options
  • Compare

    XT1540: Analog Output & Digital I/O Ethernet Modules

    • 8 Analog DC Voltage Outputs ±10V (calibrated), ±5V (sub-range)
    • 4 Discrete Voltage I/O Channels 0-32V DC
    • 12 to 32V DC Power (2.8W)
    • Modbus TCP/IP, Ethernet/IP, Profinet
    • i2o® peer-to-peer available for Modbus TCP/IP only
    The XT1540 interfaces analog output and discrete I/O signals between measurement and control devices over Ethernet. Discrete I/O are individually configurable for input or high-side switched output operation.
    Select options
  • Compare

    801A Universal TC/RTD/mV Input Intelligent Alarm

    • Thermocouple (J, K, T, R, S, E, B, N), RTD (Pt, Ni, Cu), millivolt (±100mV DC), resistance (0 to 500 ohms) input
    • Single or dual mechanical relay alarm outputs
    • 10-36V DC power
    • Software configured
    • Multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection)
    • On/off controller capability
    IntelliPack alarms compare inputs against user-defined limit set-points to control built-in relays.
    Select options
  • Compare

    801T: Universal Input Intelligent Temperature Transmitter

    • Thermocouple, RTD, milliVolt, and Resistance Input
    • 0 to 20mA DC, 0 to 10V DC output
    • Limit Alarm
    • 10-36V DC power
    • Software configured
    • Performs linearization, square root extraction, and optional limit alarm functions
    These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.
    Select options
  • Compare

    811A, 812A: Intelligent Alarm; DC Voltage/Current Input

    • ±100V or 0 to 22mA DC input ranges or 2 input channels, ±100V or 0 to 22mA DC input ranges (AC current with optional sensor)
    • Single or dual mechanical relays
    • 10-36V DC power
    • Software configured; multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection); on/off controller capability
    IntelliPack alarms compare inputs against user-defined limit set-points to control built-in relays.  
    Select options
  • Compare

    811T: DC Voltage/Current Input Intelligent Transmitter

    • ±100V or 0 to 22mA DC input ranges (AC current with optional sensor)
    • 0 to 20mA DC, 0 to 10V DC output
    • Mechanical relay alarm (25V @ 5A)
    • 10-36V DC power
    • Software configured, performs linearization, square root extraction, and optional limit alarm functions
    These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.
    Select options
  • Compare

    822A Dual Thermocouple/mV Input Intelligent Alarm

    • 2 input channels, thermocouple (types J, K, T, R, S, E, B, N), or millivolt (±100mV DC) input
    • Dual mechanical relays output
    • 10-36V DC power
    • Software configured; multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection); on/off controller capability
    IntelliPack alarms compare inputs against user-defined limit set-points to control built-in relays.
    Select options
  • Compare

    841T: DC Frequency/Pulse Input Intelligent Transmitter

    • 0 to 50KHz, 0 to 65535 pulses input
    • 0 to 20mA DC, 0 to 10V DC output
    • Mechanical alarm relay (25V @ 5A)
    • 10-36V DC power
    • Software configured; pulse counter; signal averaging; optional limit alarm functions
    These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.
    Select options
  • Compare

    892M, 894M: DC Voltage/Current Output Math Module

    • 2 or 4 input channels, 0 to 20mA DC, 0 to 10V DC (selectable ranges)
    • 0 to 20mA DC, 0 to 10V DC (selectable ranges) output
    • 10-36V DC power
    • Software configured, computes arithmetic operations, evaluates conditional and Boolean arguments, executes track & hold functions
    IntelliPack math modules perform complex mathematical computations and convert DC input signals to scaled DC or frequency outputs. They are ideal for isolating and interfacing analog signals to a PLC or controller as a voltage, current, or a pulsed input.
    Select options
  • Compare

    895M, 896M: DC Input, Frequency Output Math Module

    • 0 to 20mA DC, 0 to 10V DC (selectable ranges), 896M 2 channels input
    • 0 to 10KHz, 0 to 36,000 counts/hr Frequency output, 896M 2 channels
    • Solid-state relay (60V DC @ 500mA) control output
    • 10-36V DC power
    • Software configured, ideal for integrator/totalizer applications, computes arithmetic operations, conditional arguments, track & hold functions
    IntelliPack math modules perform complex mathematical computations and convert DC input signals to scaled DC or frequency outputs.
    Select options
  • Compare

    901MB, 902MB, 903MB: Multi-Channel Modbus-RTU Discrete I/O Modules

    • Active-Low Inputs, Sinking Outputs (Low-Side Switching)
    • 12 input and/or 12 output channels
    • 0 to 35V DC I/O range
    • 10 to 36V DC, 24V AC power
    • Modbus-RTU high-speed RS-485
    These modules provide twelve discrete input and/or output channels. Isolation separates the I/O, power, and network circuits. Network communication adheres to the industry-standard RS-485 Modbus-RTU protocol.    
    Select options