Click to zoom

Please sign in or register to see model options and to add products to your cart.

Product short description:
  • Two CAN bus channels with optional isolation
  • NXP SJA1000 CAN controller with TJA1043 transceiver

IP560: CAN Bus Interface Industry Pack Modules Description

IP560 modules provide two independent CAN bus interface channels. Each channel has a NXP SJA1000 CAN controller with a TJA1043 transceiver. The advantage of this design is that it allows reporting of bus fault conditions directly from the TJA1043 transceivers. It also has the ability to transmit, receive and perform message filtering on extended and standard messages.

Using CAN to network controllers, actuators, sensors, and transducers provides many benefits to system developers. First, the ready availability of multi-sourced components and tools can significantly reduce design time. Next, the small, light cables used by CAN help lower connection costs. Additionally, CAN has fewer connections which improves reliability.

Update to AcroPack mezzanine modules into your host system, they maintain the same functionality and memory map of Acromag’s existing Industry Pack (IP) modules. Learn More >

CAN is ideal for the following applications:

  • Marine control and navigation systems
  • Elevator control systems
  • Defense vehicles
  • Production line control systems
  • Machine tools
  • Large optical telescopes
  • Medical systems
  • Paper and textile production machinery
  • Packaging machinery

IP560: CAN Bus Interface IP Modules Features & Benefits

  • Two complete CAN bus interfaces
  • NXP SJA1000 CAN bus controller with high-speed TJA1043 CAN transceiver
  • 1000V isolation, channel-to-channel and channel-to-host (IP560-i models)
  • ISO 11898 compliance for Part A (11-bit) and Part B extended (29-bit) arbitration IDs
  • CAN 2.0B protocol compatibility (extended frame passive in PCA82C200 compatibility mode)
  • Data rates of up to 1Mb/s
  • Supports both 8MHz and 32MHz IP operation
  • 0 to 70°C or -40 to 85°C operating temperature range
  • TXD dominant clamping handler with diagnosis
  • RXD recessive clamping handler with diagnosis
  • TXD-to-RXD short-circuit handler with diagnosis
  • Bus line short-circuit diagnosis
  • Bus dominant clamping diagnosis
  • PCA82C200 mode (BasicCAN mode is default)
  • Extended receive buffer (64-byte FIFO)
  • 24 MHz clock frequency
  • PeliCAN mode extensions:
    • Error counters with read/write access
    • Programmable error warning limit
    • Last error code register
    • Error interrupt for each CAN-bus error
    • Arbitration lost interrupt with detailed bit position
    • Single-shot transmission (no re-transmission)
    • Listen only mode (no acknowledge, no active error flags)
    • Hot plugging support (software driven bit rate detection)
    • Acceptance filter extension (4-byte code, 4-byte mask)
    • Reception of ‘own’ messages (self reception request)
  • Undervoltage detection on VBAT
  • Listen-only mode for node diagnosis and failure containment

Manuals

IP560 User Manual (Log in to download the file)

Drawings & Diagrams

  • Compare

    CS-IP Conformal Coat

    Industry Pack conformal coat. This option should be selected to prevent high temperature and humidity issues (like blotching) when boards are conformal coated
    Select options

Additional information

Weight 8 oz
Dimensions 4 × 2 × 1 in
Part Number

IP560-i: isolated CAN bus interface

Product Series

Industry Pack

  • Description

    IP560: CAN Bus Interface Industry Pack Modules Description

    IP560 modules provide two independent CAN bus interface channels. Each channel has a NXP SJA1000 CAN controller with a TJA1043 transceiver. The advantage of this design is that it allows reporting of bus fault conditions directly from the TJA1043 transceivers. It also has the ability to transmit, receive and perform message filtering on extended and standard messages.

    Using CAN to network controllers, actuators, sensors, and transducers provides many benefits to system developers. First, the ready availability of multi-sourced components and tools can significantly reduce design time. Next, the small, light cables used by CAN help lower connection costs. Additionally, CAN has fewer connections which improves reliability.

    Update to AcroPack mezzanine modules into your host system, they maintain the same functionality and memory map of Acromag’s existing Industry Pack (IP) modules. Learn More >

    CAN is ideal for the following applications:

    • Marine control and navigation systems
    • Elevator control systems
    • Defense vehicles
    • Production line control systems
    • Machine tools
    • Large optical telescopes
    • Medical systems
    • Paper and textile production machinery
    • Packaging machinery

    IP560: CAN Bus Interface IP Modules Features & Benefits

    • Two complete CAN bus interfaces
    • NXP SJA1000 CAN bus controller with high-speed TJA1043 CAN transceiver
    • 1000V isolation, channel-to-channel and channel-to-host (IP560-i models)
    • ISO 11898 compliance for Part A (11-bit) and Part B extended (29-bit) arbitration IDs
    • CAN 2.0B protocol compatibility (extended frame passive in PCA82C200 compatibility mode)
    • Data rates of up to 1Mb/s
    • Supports both 8MHz and 32MHz IP operation
    • 0 to 70°C or -40 to 85°C operating temperature range
    • TXD dominant clamping handler with diagnosis
    • RXD recessive clamping handler with diagnosis
    • TXD-to-RXD short-circuit handler with diagnosis
    • Bus line short-circuit diagnosis
    • Bus dominant clamping diagnosis
    • PCA82C200 mode (BasicCAN mode is default)
    • Extended receive buffer (64-byte FIFO)
    • 24 MHz clock frequency
    • PeliCAN mode extensions:
      • Error counters with read/write access
      • Programmable error warning limit
      • Last error code register
      • Error interrupt for each CAN-bus error
      • Arbitration lost interrupt with detailed bit position
      • Single-shot transmission (no re-transmission)
      • Listen only mode (no acknowledge, no active error flags)
      • Hot plugging support (software driven bit rate detection)
      • Acceptance filter extension (4-byte code, 4-byte mask)
      • Reception of ‘own’ messages (self reception request)
    • Undervoltage detection on VBAT
    • Listen-only mode for node diagnosis and failure containment
  • Specs & Data Sheets

    Manuals

    IP560 User Manual (Log in to download the file)

    Drawings & Diagrams

  • Accessories

    • Compare

      CS-IP Conformal Coat

      Industry Pack conformal coat. This option should be selected to prevent high temperature and humidity issues (like blotching) when boards are conformal coated
      Select options
  • Additional information

    Additional information

    Weight 8 oz
    Dimensions 4 × 2 × 1 in
    Part Number

    IP560-i: isolated CAN bus interface

    Product Series

    Industry Pack