Signal Converters and Process Transmitters
Process signal transmitters and signal converters isolate, filter, amplify, and convert sensor signals to 4-20mA current or 0-10V signals for interfacing with controllers and other instrumentation. Select from 2-wire loop-powered 4-20mA transmitters, or 4-wire AC/DC-powered transmitters. Acromag offers 3- and 4-wire models with 4-20mA transmitters or voltage transmitters. DIN-rail and field-mount versions are available. Process transmitter configuration is easy with Windows® software, Agility® mobile app pushbuttons, switches, or pots for span/zero settings, depending on the series.Showing 17–32 of 34 results
-
811A, 812A: Intelligent Alarm; DC Voltage/Current Input
- ±100V or 0 to 22mA DC input ranges or 2 input channels, ±100V or 0 to 22mA DC input ranges (AC current with optional sensor)
- Single or dual mechanical relays
- 10-36V DC power
- Software configured; multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection); on/off controller capability
-
811T: DC Voltage/Current Input Intelligent Transmitter
- ±100V or 0 to 22mA DC input ranges (AC current with optional sensor)
- 0 to 20mA DC, 0 to 10V DC output
- Mechanical relay alarm (25V @ 5A)
- 10-36V DC power
- Software configured, performs linearization, square root extraction, and optional limit alarm functions
-
841T: DC Frequency/Pulse Input Intelligent Transmitter
- 0 to 50KHz, 0 to 65535 pulses input
- 0 to 20mA DC, 0 to 10V DC output
- Mechanical alarm relay (25V @ 5A)
- 10-36V DC power
- Software configured; pulse counter; signal averaging; optional limit alarm functions
-
DT337: Medium DC Voltage Input Four-Wire Dual Transmitter
- Dual channels
- ±1V, ±10V inputs
- 0-20mA, ±10V outputs
- 6-32V DC local/bus power
Click here to watch a short video highlighting the features of the DT337.
-
DT338: High DC Voltage Input Four-Wire Dual Transmitter
- Dual channels
- ±15V, ±150V inputs
- 0-20mA, ±10V outputs
- 6-32V DC local/bus power
-
ST131: Transmitter, RTD Input, Loop-Powered
- 100 ohm Pt RTD or 0-900 ohm input
- 4 to 20mA DC output
- 9-32V DC from output loop power
- USB-configured
-
ST132: Thermocouple/milliVolt Input Head-mount Transmitter
- Universal thermocouple (8 types) or ±100mV input
- 4-20mA output
- Loop-powered, 7-32V DC
-
ST133: Isolated Transmitter; Thermocouple/mV Input
- TC type J, K, T, R, S, E, B, and N or ±100mV input
- 1500V isolation
- 4 to 20mA DC output
- USB-configured
-
TT234: Potentiometer / Thermistor Input, Two-Wire Transmitter
- Potentometer / slidewire, thermister input
- 4 to 20mA output (sink / source)
- 12-32V DC loop / local power
- USB configuration
-
TT235: Isolated RTD Input, Loop Power, 2-Wire Transmitter
- Selectable RTD or linear resistance input type or 0-500 ohm input
- 4-20mA output (sink/source)
- 12-32V DC loop/local power
- USB configuration
-
TT237: Voltage Input, Loop-Power, 2-Wire Transmitter
- Multi-range ±1V, ±5V or ±10V input
- 4-20mA output (sink/source)
- 12-32 V loop power
-
TT238: High Voltage Input, Loop-Powered, 2-Wire Transmitter
- Multi-range ±15V, ±75V or ±150V DC input
- 4-20mA ouput (sink/source)
- 12-32 V DC loop power
-
TT334: Potentiometer / Thermistor Input, Four-Wire Transmitter
- Potentiometer / slidewire input
- Universal current/voltage output
- 12-32V DC local/bus power
- USB configuration
-
TT335: Isolated RTD Input, DC Local/Bus Power Transmitter
- Selectable RTD or linear resistance input type or 0-500 ohm input
- Universal output (source)
- 12-32V DC local/bus power
- USB configuration
-
TT337: Voltage Input, DC Power Transmitter
- Multi-range ±1V, ±5V or ±10V input
- Universal current/voltage output
- 12-32V DC
- 12-32V DC local/bus power
Signal Conditioners, Transmitters and Converters Continued
Acromag high-performance signal conditioner products include process transmitters, 4-20mA signal isolators, limit alarms, signal splitters, and math computation modules. These products isolate, amplify, filter, condition, and convert measured signals from sensors and other instruments. The enhanced signal is ready for interfacing to your PLC, DCS, display, recorder, or other process control instrumentation.
Temperature transmitters convert thermocouple, RTD, and low-level temperature sensor signals to 4-20mA, 0-10V, or other DC voltage/current outputs. Acromag offers temperature transmitters in head-mount and DIN-rail form factors. Some temperature transmitters have software-configured universal input to convert a broad range of temperature sensor and other signals with a single unit.
See all signal conditioners and transmitters to choose the best solution for your application.
Signal Conditioning Functions:
- Signal converter, linearizer, averager
- Integrator, totalizer
- Pulse counter, frequency measurement
- Arithmetic calculation, Boolean logic
- Limit alarm relay trip, window range, deviation, rate-of-change, peak/valley detection
Learn More About Transmitters