Signal Conditioners, Transmitters, and Converters

Process signal conditioners and transmitters isolate, filter amplify, and convert sensor signals to 4-20mA current or 0-10V voltage signals for interfacing with controllers and other instrumentation. Select from 2-wire loop-powered 4-20mA transmitters, 3-wire DC-powered transmitters, or 4-wire AC/DC-powered transmitters. 3-wire and 4-wire models are available as 4-20mA transmitters or voltage transmitters. DIN-rail and field-mount version are available. Process transmitter configuration is easy with Windows software, push-buttons, switches, or pots for span/zero settings depending on the series.

Showing 1–16 of 39 results

  • Compare

    DT233: Thermocouple/milliVolt Input Two-wire Dual Transmitter

    • Dual channels
    • Universal thermocouple, mV input
    • 4-20mA outputs (sink/source)
    • 7-32V DC loop/local
    The DT233 model is a dual two-wire transmitter that isolates and converts millivolt or thermocouple sensor inputs to proportional 4-20mA control signals. Power is received from the output loop current.
    $315
    Select options
  • Compare

    DT333: Thermocouple/milliVolt Input Four-wire Dual Transmitter

    • Dual channels
    • Universal thermocouple, mV inputs
    • Isolated current or voltage outputs
    • 6-32V DC local/bus power
    The DT333 model is a four-wire dual transmitter that isolates and converts millivolt or thermocouple sensor inputs to proportional control signals. Each channel supports DC current or voltage output.
    $370
    Select options
  • Compare

    TT233: Thermocouple/Millivolt Input Two-Wire Transmitter

    • Universal TC type J, K, T, R, S, E, B, N or ±100mV input
    • 4-20mA ouput (sink/source)
    • 12-32 V DC loop/local power
    The TT233 model is a space-saving two-wire transmitter that isolates and converts a millivolt or thermocouple sensor input to a proportional 4-20mA control signal. Power is received from the output loop current or a DC supply when using a three-wire connection.
    $195
    Select options
  • Compare

    TT236: Current/milliVolt Input Two-Wire Transmitter

    • Multi-range ±20mA or ±500mV input
    • 4-20mA ouput (sink/source)
    • 12-32 V DC loop/local power
    The TT236 model is a space-saving two-wire transmitter that isolates and converts a DC current or low voltage input to a proportional 4-20mA control signal. A single unit supports both voltage and current input for extra flexibility. Power is received from the output loop current or a DC supply when using a three-wire connection.
    $195
    Select options
  • Compare

    TT239: Frequency/Pulse/PWM Input, 12-32V DC Loop Power, 2-Wire Transmitter

    • Multi-range 0Hz to 100KHz frequency input
    • Multi-range 0Hz to 3KHz PWM input
    • 4-20mA output (sink/source)
    • 12-32V DC power
    The TT239 model is a space-saving two-wire transmitter that isolates and converts a frequency, pulse, or pulse-width modulation (PWM) input to a proportional 4-20mA signal. You can select to measure either the input frequency or the duty cycle. Power is received from the output loop current or a DC supply when using a three-wire connection.
    $195
    Select options
  • Compare

    TT333: Thermocouple/milliVolt Input Four-wire Transmitter

    • Universal thermocouple / millivolt input
    • Universal current / voltage output
    • 12-32V DC local / bus power
    The TT333 model is a space-saving four-wire transmitter that isolates and converts a millivolt or thermocouple sensor input to a proportional control signal. DC current and voltage output are both supported on a single model.
    $265
    Select options
  • Compare

    TT336: Current/milliVolt Input, DC Power Transmitter

    • Multi-range ±20mA or ±500mV input
    • Universal current/voltage output
    • 12-32V DC power
    DC current and voltage output are both supported on a single model. An optional DIN rail bus can deliver primary or redundant power to multiple units without wiring.
    $265
    Select options
  • Compare

    TT339: Frequency/Pulse Input, 12-32V DC Local/Bus Power Transmitter

    • Multi-range 0Hz to 100KHz input
    • Universal current/voltage output
    • 12-32V DC local/bus power
    $265
    Select options
  • Compare

    DT236: Current/milliVolt Input Two-wire Dual Transmitters

    •  Dual channels
    •  ±20mA, ±500mV inputs
    • 4-20mA outputs (sink/source)
    • 7-32V DC loop power
    The DT236 model is a dual two-wire transmitter that isolates and converts DC current or low voltage inputs to proportional 4-20mA control signals. Power is received from the output loop current or a DC supply when using a three-wire connection.
    $270
    Select options
  • Compare

    DT235: RTD/resistance Input Two-wire Dual Transmitter

    • Dual channels
    • RTD (Pt, Ni, Cu), 0-4500 ohm inputs
    • 4-20mA output (sink/source)
    • 7-32V DC loop power
    The DT235 model is a two-wire dual transmitter that isolates and converts RTD or linear resistance sensor inputs to a proportional 4-20mA control signal.
    $290
    Select options
  • Compare

    DT336: Current/Voltage Input Four-wire Dual Transmitter

    • Dual channels
    • ±20mA, ±500mV inputs
    • 0-20mA, ±10V outputs
    • 6-32V DC local/bus power
    $325
    Select options
  • Compare

    DT335: RTD/Resistance Input Four-wire Dual Transmitter

    • Dual channels
    • RTD (Pt, Ni, Cu) or 0-4500 ohm input
    • 0-20mA, ±10V outputs
    • 6-32V DC local/bus power
    DT330 series signal conditioners provide two independent I/O channels in a single, space-saving unit. The DT335 model is a four-wire dual transmitter that isolates and converts RTD or linear resistance sensor inputs to proportional control signals.
    $340
    Select options
  • Compare

    DT237: Medium DC Voltage Input Two-wire Dual Transmitter

    • Dual channels
    •  0-10V, ±10V inputs
    • 4-20mA outputs (sink/source)
    • 7-32V DC loop power
    DT230 series signal conditioners provide two independent I/O channels in a single, space-saving unit. The DT237 model is a two-wire dual transmitter that isolates and converts high-level DC voltage inputs to a proportional 4-20mA control signal. Power is received from the output loop current or a DC supply when using a three-wire connection.
    $285
    Select options
  • Compare

    DT238: High DC Voltage Input Two-wire Dual Transmitter

    • Dual inputs
    • 0±150V input
    • 4-20mA outputs (sink/source)
    • 7-32V DC loop/local power
    $300
    Select options
  • Compare

    TT231: RTD/Resistance Input Two-Wire Transmitter

    • 100 ohm Pt RTD or 0-900 ohm input
    • 4-20mA output (sink/source)
    • 12-32V DC loop/local power
    • USB configuration
    The TT231 model is a space-saving two-wire transmitter that converts a 100 ohm Platinum RTD sensor input to a proportional 4-20mA signal. Power is received from the output loop current or a DC supply when using a three-wire connection.
    $195
    Select options
  • Compare

    801A: Intelligent Alarm, Universal TC/RTD/mV Input

    • Thermocouple (J, K, T, R, S, E, B, N), RTD (Pt, Ni, Cu), millivolt (±100mV DC), resistance (0 to 500 ohms) input
    • Single or dual mechanical relay alarm outputs
    • 10-36V DC power
    • Software configured
    • Multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection)
    • On/off controller capability
    $375$415
    Read more

Signal Conditioning Selection Guide Videos

Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.

Output Loop Powered Transmitters Video

DC Powered Transmitters Options Video

AC Powered Transmitters

Alarms