Showing all 6 results

  • Compare

    DT235: RTD / Resistance Input Two-Wire Dual Transmitter

    • Dual channels
    • RTD (Pt, Ni, Cu), 0-4500 ohm inputs
    • 4-20mA output (sink/source)
    • 7-32V DC loop power
    The DT235 model is a two-wire dual transmitter that isolates and converts RTD or linear resistance sensor inputs to a proportional 4-20mA control signal.

    Click here to watch a short video highlighting the features of the DT235.

    Select options
  • Compare

    TT231: RTD / Resistance Input Two-Wire Transmitter

    • 100 ohm Pt RTD or 0-900 ohm input
    • 4-20mA output (sink/source)
    • 12-32V DC loop/local power
    • USB configuration
    The TT231 model is a space-saving two-wire transmitter that converts a 100 ohm Platinum RTD sensor input to a proportional 4-20mA signal. Power is received from the output loop current or a DC supply when using a three-wire connection. Click here to watch a short AcroMaggie video highlighting the TT230 Series.
    Select options
  • Compare

    657T, 658T: Single or Dual Channel, RTD Input, Loop-powered Transmitter

    • 100 ohm Pt, 120 ohm Ni, 10 ohm Cu (selectable type) input
    • 4 to 20mA DC output
    • 12-50V DC from output loop power
    • DIP-switch configuration, push-button calibration
    These units accept universal RTD or resistance input signals and output proportional DC current signals. The output can also be linearized to the input sensor signal.
    Select options
  • Compare

    ST131: Transmitter, RTD Input, Loop-Powered

    • 100 ohm Pt RTD or 0-900 ohm input
    • 4 to 20mA DC output
    • 9-32V DC from output loop power
    • USB-configured
    The ST131 is a low-cost two-wire transmitter that converts a 100 ohm Platinum RTD sensor input to a proportional 4-20mA signal. Power is received from the output loop current.
    Select options
  • Compare

    TT235: Isolated RTD Input, Loop Power, 2-Wire Transmitter

    • Selectable RTD or linear resistance input type or 0-500 ohm input
    • 4-20mA output (sink/source)
    • 12-32V DC loop/local power
    • USB configuration
    The TT235 model is a space-saving two-wire transmitter that isolates and converts an RTD sensor input to a proportional 4-20mA signal. Power is received from the output loop current or a DC supply when using a three-wire connection. Click here to watch a short AcroMaggie video highlighting the TT230 Series.
    Select options
  • Compare

    250T-RB, 350T-RB, 450T-RB Loop, DC, or AC-Power Transmitter

    • Platinum RTD or Copper RTD (resistance temperature sensor) Input
    • DC Voltage/Current Output
    Select options