Click on a brochure title to download your brochure.

Ethernet I/O

High-Density Isolation Amplifiers and Analog Signal Conditioners

Multi-Function Alarms

Panel Meters

Transmitters and Isolators

Wireless I/O Modules


Monitoring and Control Solutions Process Products Summary Guide  (16 pages, 6MB PDF)
Sixteen page, signal conditioning and network I/O product line overview brochure.
Please send me a brochure by mail.


Ethernet I/O

900EN_Series_Brochure_Cover

BusWorks® 900EN Series Ethernet I/O Brochure (28 pages, 6MB PDF)
Protocol: ModbusTCP/IP, Ethernet/IP
Programming: Built-in Web pages via internet browser save with Copy Utility
Special Features: Sinking or sourcing DO, Peer-to-peer i2o, counter/totalizers, 16-bit signed registers, 32-bit floating point registers, 1 Ethernet port, high speed models, watchdog timers, 1500V AC Isolation, operating temperature -25°C to + 70°C, CE, UL, cUL, Class 1 Div 2.


XT Series Brochure Cover

BusWorks® XT Series Ethernet I/O Brochure  (31 pages, 6MB PDF)
Protocol: ModbusTCP/IP, Ethernet/IP, Profinet
Programming: USB configured with Acromag XT-SIP software. Save as file & easy download
Special Features: Sinking or sourcing DO, Peer-to-peer i2o, 16-bit signed registers, 2 Ethernet ports, high speed models, watchdog timers, redundant power, 1500V AC isolation, 25G shock, 4G vibration, operating temperature -40° to +70°C. CE Compliant. UL/cUL Class 1 Div 2 Zone 2 approvals. ATEX Certified.


Etherstax Brochure Cover

EtherStax Brochure (38 pages, 8MB PDF)
Protocol: ModbusTCP/IP, Modbus UDP/IP
Programming: Built-in Web pages via internet browser save with Copy Utility
Special Features: Sinking DO & relay outputs, Peer-to-peer i2o, counter/totalizers, 16-bit signed registers, 32-bit floating point registers, 2 Ethernet ports – hub or switch, high speed models, watchdog timers, redundant power, 1500V AC isolation, 50G shock, 5G vibration, operating temperature -40° to +75°C, CE, UL, cUL, Class 1 Div 2.


High-Density Isolation Amplifiers and Analog Signal Conditioners

microBlox® Series Signal Conditioner Brochure  (7 pages, 4MB PDF)
Special Features: Cost-saving commercial grade versions, User-configurable I/O ranges with smartphone or tablet, INput polling with trend charts in Android® or iOS® app, Alarm output function with setpoint and deadband, 1500Vac isolation field-to-host and channel-to-channel, Up to 0.05% accuracy and 130db CMR, Shock and vibration-resistant without screws.

Go to Top of Page


Multi-Function Alarms

IntelliPack 800A Intelligent Alarms Brochure (14 page 757KB PDF)
Input: Thermocouple, RTD, DC millivolt, DC Volt/Current
Output: Single DPDT electro-mechanical 5A relay (-0100), Dual SPDT electro-mechanical 5A relays (-0200)
Power: DC Voltage
Special Features: Integrated microcontroller performs intelligent signal processing for advanced alarm functions, Windows XP/Vista/7 software configuration speeds setup and replacement, Push-button reprogrammability facilitates changes in the field without a host PC, Multi-purpose inputs accept numerous ranges to reduce spare stock requirements, High-resolution Sigma-Delta A/D converter delivers high accuracy with low noise, input excitation supply on each input provides power for a two-wire transmitter, Dual alarm operation lets you perform two alarm functions at the same time.


IntelliPack 800T Intelligent Alarms Brochure (15 page 2MB PDF)
Input: Thermocouple, RTD, DC millivolt, Resistance, DC Voltage/Current, Frequency/Pulse Counter, Strain Gauge/Load Cell
Output: DC Voltage/Current
Power: DC Voltage
Special Features: High-resolution Sigma-Delta A/D converter delivers high accuracy with low noise, Advanced microcontroller provides intelligent signal processing power for linearization, averaging, and square root computations, Windows XP/Vista/7 software configuration speeds setup and replacement, Multi-purpose inputs and outputs reduce spare stock requirements, Relay output option provides local limit alarm capability.


Acromag Math Computation Modules

IntelliPack 890M Intelligent Alarms Brochure (10 page 481KB PDF)
Input: Single, Dual, and Quad DC Voltage/Current Input
Output: Universal DC Voltage/Current, Frequency/Pulse
Special Features: Universal DC analog I/O ranges provide flexibility for changing application requirements, Individual channel input/output scaling displays signal values in engineering units, Track and hold function enables easy identification of critical events and their corresponding signal values, 200-character equation fields (50-char. max. on 895/896M) support complex transfer functions, Software simulation feature allows off-line testing of equations to quickly check output signal response for a variety of conditions, Excitation supply for two 2-wire transmitters provides 15V DC @ 48mA to eliminate need for additional power supplies (892/894M only), Diagnostic LEDs provide quick, visual indication of an out-of-range input value.


microBlox_Cover

uBTA Universal Alarms Brochure (15 Page 3MB PDF)
Special Features: Dual alarms (hi/hi, lo/lo, hi/lo) with two independent mechanical or solid-state relays, Mechanical relays switch 5A at 250V AC or 30V DC, Transmitter output with scalable 0-20mA, 4-20mA, and 0-5V signal ranges, Interchangeable input modules for measuring a wide variety of signal types, Easy configuration using Bluetooth wireless technology with smartphone or tablet running Acromag Agility app for Android® and iOS®, High accuracy alarm and transmitter output, High noise immunity and stability, High voltage isolation between input, output, relay contacts, and power, All I/O and power ports transient-protected, Wide -40 to 75°C operating range, UL/cUL Class I, Div 2, ABCD and ATEX Zone 2 hazardous location approvals (pending).


Panel Meters

VPM3000 Data Sheet (2 pages 760KB PDF)
Inputs: 4-20mA, ±10V, thermocouple, or RTD
Output Options: 4-20mA, Modbus serial, or alarm relay
Power Options:
85-265V AC, 50/60 Hz
90-265V DC, 20 W max.
or 12-24V AC or 12-36V DC, 6 W max
Special Features: Can operate as a transmitter and/or alarm. Has large, bright display


APM765 Data Sheet (4 pages 680KB PDF)
Inputs: Universal input (TC, RTD, mA, V DC)
Output Options: Isolated 4-20mA and Modbus
Power Options:
85-265V AC or 90-265V DC power
optional: 12-24V AC or 12-36V DC power
Special Features: Push-button or PC programmable

Go to Top of Page


Transmitters and Isolators

Acromag 600T Series Transmitters

600T Series 2/4-Wire Isolated Transmitter Brochure (21 page 2MB PDF)
Input: DC voltage, DC current, thermocopule/millivolt, RTD/resistance, AC current
Output: DC current, DC voltage
Power: DC voltage, current, splitter
Special Features: Auto-config self-ranging, CE, UL/cUL Class 1 Div 2 Groups A, B,C, D


DT230 Series Brochure (20 page, 6MB PDF)
Special Features: 2/3/4-Wire RTD/Resistance Input, USB Programmable, DIN Rail Mount, Dual Isolated Transmitter for RTD/Resistance Inputs and Passive 2-Wire 4-20mA Transmitter Outputs.


DT330 Series Brochure (20 page, 6MB PDF)
Special Features: USB Programmable DC-Powered Dual/Single Transmitter or Signal Splitter
DT333 Dual Input Transmitter for Thermocouple & ±mV/±1V Input
DT336 DC Current & Low DC Voltage Input
DT337 DC ±1V/±10V Medium Voltage Input
DT338 DC ±15V/±150V High Voltage Input


SP230 Series Brochure (18 page, 6MB PDF)
Input: Thermocouple, AC/DC current, millivolt/voltage
Output: 4-20mA current (sink or source)
Power: 7-32V DC loop/local power
Special Features: Space saving 17.5mm housing; Easy setup via USB with Windows® configuration software; Supports sink/source wiring; 2-wire, loop-powered; -40 to 80°C; Current, voltage, and temperature splitters; Adjustable filtering levels; Ability to scale inputs differently for each output; Shock and vibration resistant; CE Compliant. UL/cUL Class 1 Div 2 Zone 2 approvals; ATEX and IECEx Certified.


SP330 Series Brochure Cover

SP330 Series Brochure (18 page, 6MB PDF)
Input: Thermocouple, AC/DC current, millivolt/voltage
Output: scalable current or voltage output
Power: 6-32V DC external power
Special Features: Space saving 17.5mm housing; Easy setup via USB with Windows® configuration software; Supports sink/source wiring; 4-wire, externally powered; -40 to 75°C; Current, voltage, and temperature splitters; Adjustable filtering levels; Ability to scale inputs differently for each output; Shock and vibration resistant; CE Compliant. UL/cUL Class 1 Div 2 Zone 2 approvals; ATEX and IECEx Certified.


ST130 Series Head-Mount Transmitters Brochure (7 Page 2MB PDF)
Input: Universal Thermocouple (8 types), millivolt
Output: 4 to 20mA DC
Power: Loop-power, 9-32V DC, 7-32V DC
Special Features: Easy setup and digital calibration via USB with Windows configuration software, Flexible RTD or linear resistance input ranges, Supports any 100 ohm Pt RTD (375-393 alpha), High accuracy and linearity, Advanced analog signal conditioning ASIC eliminates digitization errors, Low temperature drift, Fast response time, Programmable over/under-range limits, Selectable upscale or downscale operation for sensor errors and lead-break detection, NAMUR NE43 compliant fault response, Reverse polarity protected with non-polarized output, Mounts in DIN Form 8 sensor heads, Optional DIN rail adapter, Wide ambient operation, Hardened for harsh environments, CE Compliant: UL/cUL Class 1 Div 2 Zone 2 approvals, ATEX certified.


TT230 Series 2/3-Wire Isolated Transmitter Brochure (7 page 3MB PDF)
Input: 4-20mA isolator, voltage, millivolt, RTD, resistance, frequency, potentiometer, thermistor, pulse-width-modulated, AC current
Output: 4-20mA current (sink or source)
Power: Loop-power (2-wire connection), Local DC power source (3-wire connection)
Special Features: Space saving 12.5mm housing, USB configuration using Windows®, supports sink and souce output in a single model, 0.1% accuracy, 1500V AC isolation, high speed models, adjustable filtering levels, normal/reverse acting operation, shock and vibration resistant, operating temperature -40° to +80°C. CE Compliant. UL/cUL Class 1 Div 2 Zone 2 approvals. ATEX Certified.


TT330 Series Brochure Cover

TT330 Series 4-Wire Isolated Transmitter Brochure (24 page 6MB PDF)
Input: Thermocouple/millivolt, potentiometer/thermistor, RTD, current/millivolt, low voltage, high voltage, frequency pulse
Output: Universal current/voltage: ±10V, ±5V, 0-10V, 0-5V, ±20mA, 0-20mA, 4-20mA
Power: 12-32V DC local/bus power
Special Features: Space saving 17.5mm housing, USB configuration using Windows®, supports unipolar and bipolar input ranges up to ±20mA or ±500mV DC, 1500V AC isolation, normal/reverse acting output, shock and vibration resistant, operating temperature -40° to +80°C. CE Compliant. UL/cUL Class 1 Div 2 Zone 2 approvals. ATEX Certified.


microBlox_Cover

uBTA Universal Transmitters Brochure (15 Page 3MB PDF)
Special Features: Dual alarms (hi/hi, lo/lo, hi/lo) with two independent mechanical or solid-state relays, Mechanical relays switch 5A at 250V AC or 30V DC, Transmitter output with scalable 0-20mA, 4-20mA, and 0-5V signal ranges, Interchangeable input modules for measuring a wide variety of signal types, Easy configuration using Bluetooth wireless technology with smartphone or tablet running Acromag Agility app for Android® and iOS®, High accuracy alarm and transmitter output, High noise immunity and stability, High voltage isolation between input, output, relay contacts, and power, All I/O and power ports transient-protected, Wide -40 to 75°C operating range, UL/cUL Class I, Div 2, ABCD and ATEX Zone 2 hazardous location approvals (pending).

Go to Top of Page


Wireless I/O Modules

VWB2000 Point-to-Point Wireless IO Modules

VWB2000 Series: Point-to-Point Wireless Analog and Digital I/O Signal Bridge Data Sheet (2 Page, 978KB PDF)
Special Features: The Acromag VWB2000 wireless I/O system provides a simple solution to reproduce an analog, discrete, or Modbus® signal at a remote location. This point-to-point wireless bridge is easy to set up and enclosed in a rugged, weather-tight housing to meet the demands of industrial installations. The system consists of two pre-paired transmitter/receiver units. Connect analog, discrete, or Modbus® inputs to one unit and wirelessly broadcast signal data to the other unit. The receiving unit recreates the original signal for output to local instrumentation. Install the units in the factory or field – anywhere you have 12-28V DC power.

Go to Top of Page