Showing 33–48 of 48 results

  • Compare

    965EN: Ethernet Thermocouple milliVolt Input Modules

    • 4 or 6-channel thermocouple/milliVolt input
    • Ethernet/IP, Modbus TCP/IP
    • i2o peer-to-peer available for Modbus TCP/IP 6-channel only
    These modules provide an isolated Ethernet network interface for up to six input channels. Differential inputs eliminate ground noise and each terminal block includes a cold junction compensation (CJC) sensor for more precise temperature measurements. Multi-range inputs accept signals from a variety of sensors and devices. High-resolution, low noise, A/D converters deliver high accuracy and reliability.    
    Select options
  • Compare

    965PB: 4 or 6-Channel Thermocouple/mV Input Profibus-DP Modules

    • Thermocouple or Millivolt Signals
    • 4 or 6 input channels, thermocouple or DC millivolts (user-selectable)
    • 12 to 36V DC  power
    • Profibus-DP, RS-485 network up to 12Mbaud
    These modules provide an isolated Profibus-DP network interface for up to six input channels. Differential inputs eliminate ground noise.
    Select options
  • Compare

    966EN: Ethernet RTD Resistance Input Modules

    • 4 or 6-channel RTD/resistance input
    • Ethernet/IP, Modbus TCP/IP
    • i2o peer-to-peer available for Modbus TCP/IP 6-channel only
    These modules provide an isolated Ethernet network interface for up to six input channels. Multi-range inputs accept signals from a variety of sensors and devices. High-resolution, low noise, A/D converters deliver high accuracy and reliability. Three-way isolation further improves the system performance.  
    Select options
  • Compare

    966PB: 4 or 6-Channel RTD/Resistance Input Profibus-DP Modules

    • RTD or Resistance Signals
    • 4 or 6 input channels, Platinum 100 ohm, Nickel 120 ohm, Copper 10 ohm; 0 to 500 ohms resistance
    • 12 to 36V DC power
    • Profibus-DP, RS-485 network up to 12Mbaud
    These modules provide an isolated Profibus-DP network interface for up to six input channels. Multi-range inputs accept signals from a variety of sensors and devices.
    Select options
  • Compare

    967EN: Ethernet Analog Input Modules

    • 8-channel differential current input
    • Modbus TCP/IP, 10/100Base-T(X), i2o peer-to-peer
    These modules interface high-level analog input signals to an Ethernet network. A high-performance design ensures reliable measurements and dependable operation.
    Select options
  • Compare

    968EN: Ethernet Analog Input Module

    • 8-channel differential analog voltage input
    • Modbus TCP/IP, i2o peer-to-peer communication
    These modules interface high-level analog input signals to an Ethernet network. A high-performance design ensures reliable measurements and dependable operation.
    Select options
  • Compare

    972EN, 973EN: Ethernet Analog Output Modules

    • 4 or 6-channel DC current or voltage output
    • Ethernet/IP, Modbus TCP/IP
    • i2o peer-to-peer available for Modbus TCP/IP only
    These modules provide up to six channels of analog output. Multi-range outputs support a wide variety of industrial devices. They can drive displays and recorders, control drives, or send analog signals to other systems. High-resolution, low noise, D/A converters deliver high accuracy and reliability. Three-way isolation further improves system performance.
    Select options
  • Compare

    972PB, 973PB: Analog Output Profibus-DP - RS485 Modules

    • 0 to 1mA, 0 to 20mA, or 4 to 20mA DC Current Output; 0 to 1V, 0 to 5V or 0 to 10V DC Output
    • 12 to 36V DC Power
    • Profibus-DP, RS-485 network up to 12Mbaud
    These modules provide up to six channels of analog output. Multi-range outputs support a wide variety of industrial devices.
    Select options
  • Compare

    981EN, 982EN, 983EN: Ethernet Discrete I/O Modules

    • 12-channel discrete input and/or output
    • Ethernet/IP, Modbus TCP/IP
    • i2o peer-to-peer available for Modbus TCP/IP
    These modules provide an isolated Ethernet network interface for twelve discrete input and/or output channels. The outputs provide direct on/off, high/low, or open/close control of industrial devices. The inputs sense the status of motors, pumps, valves and other equipment. The 983EN model with tandem I/O provides output level control and status verification in one unit.
    Select options
  • Compare

    981PB, 982PB, 983PB: Profibus-DP 12-Channel Digital I/O

    • Active-Low Inputs, Sinking Outputs
    • 12 input channels, 0 to 35V DC range
    • 12 to 36V DC
    • High-speed RS-485
    These modules provide an isolated Profibus-DP network interface for twelve discrete input and/or output channels. The outputs provide direct on/off, high/low, or open/close control of industrial devices.
    Select options
  • Compare

    989EN: Ethernet Discrete I/O Modules with Counter / Timers

    • 16-channel discrete I/O
    • 8 counter/timers
    • Modbus TCP/IP communication
    These modules provide an isolated Ethernet interface for any input/output mix of up to 16 discrete signals. Inputs sense the status of dry contacts, switches, power supplies, and DC logic. Industrial-grade units have eight 32-bit counters with timers, alarms, and non-volatile memory for metering, totalizing, and low-frequency periodic measurement. The outputs control solid-state switching of lamps, horns, and other devices.
    Select options
  • Compare

    993EN: Ethernet Analog Input Modules

    • 16-channel single-ended analog current input
    • Modbus TCP/IP communication
    These modules interface high-level analog input signals to an Ethernet control network. A high-performance design ensures reliable measurements and dependable operation. Industrial-grade models add a configurable integrator/totalizer plus superior accuracy and temperature performance compared to the economical commercial-grade version.
    Select options
  • Compare

    994EN: Ethernet Analog Input Module

    • 16-channel single-ended analog voltage input
    • Modbus TCP/IP communication
    These modules interface high-level analog input signals to an Ethernet control network. A high-performance design ensures reliable measurements and dependable operation. Industrial-grade models add a configurable integrator/totalizer plus superior accuracy and temperature performance compared to the economical commercial-grade version.
    Select options
  • Compare

    Profibus-DP GSD Files

    • Download GSD files from the Software Tab
    Read more
  • Compare

    XTA-120V-6: Solid-State Relay Input Modules

    • 6 optocoupler channels
    • 120V AC/DC input with optical isolation
    • Universal 5/12/24V logic output
    The XTA-120V-6 optocoupler module provides six individually isolated 120V AC/DC digital (discrete) inputs to sense on/off levels and drive open-drain outputs. It is intended for use with BusWorks XT Series discrete I/O and other digital input modules to monitor contact closures or mains power supply high/low voltage levels.
    Select options
  • Compare

    XTA-MRNO-6: Mechanical Relay Output Modules

    • 6 digital I/O channels
    •  Universal 5/12/24V logic inputs
    •  Form A, 250V AC / 30V DC @ 5A relay outputs
    The XTA-MRNO-6 is an interposing relay module with six digital inputs and six mechanical relay outputs. It is intended for use with BusWorks XT Series discrete I/O or other digital output modules for the purpose of driving high energy loads.
    Select options